2017
DOI: 10.1016/j.chemolab.2016.12.010
|View full text |Cite
|
Sign up to set email alerts
|

A scoring metric for multivariate data for reproducibility analysis using chemometric methods

Abstract: Process quality control and reproducibility in emerging measurement fields such as metabolomics is normally assured by interlaboratory comparison testing. As a part of this testing process, spectral features from a spectroscopic method such as nuclear magnetic resonance (NMR) spectroscopy are attributed to particular analytes within a mixture, and it is the metabolite concentrations that are returned for comparison between laboratories. However, data quality may also be assessed directly by using binned spectr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
25
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 13 publications
(25 citation statements)
references
References 29 publications
(34 reference statements)
0
25
0
Order By: Relevance
“…Use of this code allows researchers to identify laboratories producing data closest to the consensus values, thereby ensuring that untargeted studies are using the most precise data available to them. The software was originally developed for analyzing nuclear magnetic resonance spectroscopic data [1,2] but can be applied to nearly any array data, including Raman or Fourier-transform infrared spectroscopy and gas or liquid chromatography. Details on the implementation of the code can be found in Ref.…”
Section: Discussionmentioning
confidence: 99%
“…Use of this code allows researchers to identify laboratories producing data closest to the consensus values, thereby ensuring that untargeted studies are using the most precise data available to them. The software was originally developed for analyzing nuclear magnetic resonance spectroscopic data [1,2] but can be applied to nearly any array data, including Raman or Fourier-transform infrared spectroscopy and gas or liquid chromatography. Details on the implementation of the code can be found in Ref.…”
Section: Discussionmentioning
confidence: 99%
“…In keeping with the goal of QC materials characterized by analytical profiles rather than by a defined composition, we have not attempted to assign an identity to any of the features in the profiles and PCA is done only on the intensity data. Ideally, we would perform consistency analysis as done in previous studies [4], but there is not enough data from the ILS for this analysis. However, for the LC-MS analysis, putative assignments were given for overlapping features that were found in all four labs.…”
Section: Methodsmentioning
confidence: 99%
“…A large part of the long development time for CRMs is the requirement for full, multi-platform validation of the materials with certified value assignment before they are released with a certificate of analysis (COA) by their producers [3]. It is much easier in the QC material paradigm to perform some smaller number of qualifying tests for a QC material and release it into the consensus-building community compared to the strict data quality and validation requirements for producing a CRM [4].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…1 In some cases, the reported results by participants are multivariate data and univariate techniques are not suitable to analyze this kind of data. 2 For this situation, multivariate analysis techniques can be used for investigating the inherent structure of data without losing valuable information of measurement.…”
Section: Introductionmentioning
confidence: 99%