2021
DOI: 10.1016/j.measurement.2020.108576
|View full text |Cite
|
Sign up to set email alerts
|

A selective multiple fit method of the point of inflection for the large-area HTFP melting plateau curve

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 21 publications
0
4
0
Order By: Relevance
“…Traditionally, the aforementioned methods have been developed to calculate the POI of the melting plateau of smallarea cells with a duration of a few minutes. Recently, in [29], a new selective multiple fit method for evaluating the largearea HTFP melting plateau was proposed and implemented. Similar to the previous method [5], this method also uses firstand second-order derivatives of the melting plateau to determine the start and end points but uses an interval between the inner and outer limits as a fitting range for a third-order polynomial fit.…”
Section: The Point Of Inflection (Poi)mentioning
confidence: 99%
“…Traditionally, the aforementioned methods have been developed to calculate the POI of the melting plateau of smallarea cells with a duration of a few minutes. Recently, in [29], a new selective multiple fit method for evaluating the largearea HTFP melting plateau was proposed and implemented. Similar to the previous method [5], this method also uses firstand second-order derivatives of the melting plateau to determine the start and end points but uses an interval between the inner and outer limits as a fitting range for a third-order polynomial fit.…”
Section: The Point Of Inflection (Poi)mentioning
confidence: 99%
“…The melting and freezing plateau were realized by applying the furnaces step of +15 K above and −15 K below the melting point of WC-C. The melting points of the WC-C blackbodies was determined as the POI of the melting plateau using the new 'selective multiple fit method' developed at NIM [21]. Using the second derivative of the melting curve, we obtained the The comparison of the large-and small-cell WC-C blackbodies was performed in different three days.…”
Section: Large-area Wc-c Blackbody Temperature Measurementmentioning
confidence: 99%
“…In order to meet the increasing needs for high accuracy calibration of spectral irradiance in various fields in China, a large-area WC-C high temperature fixed-point blackbody system was set up at NIM, which is composed of a 14 mm diameter WC-C cell and a BB3500MP furnace with a radiator inner diameter of 59 mm in 2019 [20,21]. Based on the large area WC-C HTFP, NIM put forwarded a method for spectral irradiance measurement of the FEL lamp in the wavelength from 450 nm to 1000 nm [20].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation