A selective optical sensor for beryllium determination based on incorporating of 1,8-dihydroxyanthrone in a poly (vinyl chloride) membrane

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 41 publications
0
5
0
Order By: Relevance
“…In addition, the industrial applications (e.g. oxide thin films, oxide nanoparticles, oxide nanotubes, and dopant for optical, magnetic, and electronic materials) are increasing remarkably in the last decade, because beryllium and its oxide possess high thermal conductivity, high melting point, high mechanical strength, high insulation nature, and high chemical and thermal stabilities . However, beryllium is unfortunately associated with severe respiratory diseases; thus, the detailed complexation behavior of beryllium ion will be very useful to detect the beryllium in environmental pollution.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, the industrial applications (e.g. oxide thin films, oxide nanoparticles, oxide nanotubes, and dopant for optical, magnetic, and electronic materials) are increasing remarkably in the last decade, because beryllium and its oxide possess high thermal conductivity, high melting point, high mechanical strength, high insulation nature, and high chemical and thermal stabilities . However, beryllium is unfortunately associated with severe respiratory diseases; thus, the detailed complexation behavior of beryllium ion will be very useful to detect the beryllium in environmental pollution.…”
Section: Introductionmentioning
confidence: 99%
“…However, more enhancement of the microcantilevers' surface properties is possible. In addition to the above, a Be 2+ optode optical sensor was crafted by Beiraghi A et al In this, the membrane was prepared by adding 1,8-dihydroxy anthrone and sodium tetraphenyl borate (NaTPB) to a plasticized poly-vinyl chloride membrane using ortho-nitrophenyl octyl ether (o-NPOE) as a plasticizer (Beiraghi et al, 2011). When exposed to Be 2+ ions at pH 10.5, the detecting membrane's color changed rapidly from orange to red.…”
Section: Biosensors For the Detection Of Berylliummentioning
confidence: 99%
“…After sample pretreatments [34], 3 ml of each sample was spiked with appropriate amount of Ni (II) and was subjected to the above procedure.…”
Section: Chemicalsmentioning
confidence: 99%