A semi-analytical method for determining unsteady temperature field in a parallel-flow three-fluid heat exchanger

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
12
0

Year Published

2005
2005
2019
2019

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 11 publications
(13 citation statements)
references
References 0 publications
1
12
0
Order By: Relevance
“…The correctness of the mathematical model adopted and the method of solution used is verified by comparing the results obtained from the numerical method with those from a semi-analytical solution for the case of a co-current three-fluid heat exchanger with two thermal couplings [10]. The present model with three thermal 13 couplings, accounting for the thermal capacity of the walls and heat conduction along the walls, is reduced to the model analysed in the work [10] Verifying calculations are carried out assuming that the system, initially at steady-state, undergoes an exponential rise of the inlet temperature of the fluid flowing through channel no.…”
Section: Validation Of the Model And Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The correctness of the mathematical model adopted and the method of solution used is verified by comparing the results obtained from the numerical method with those from a semi-analytical solution for the case of a co-current three-fluid heat exchanger with two thermal couplings [10]. The present model with three thermal 13 couplings, accounting for the thermal capacity of the walls and heat conduction along the walls, is reduced to the model analysed in the work [10] Verifying calculations are carried out assuming that the system, initially at steady-state, undergoes an exponential rise of the inlet temperature of the fluid flowing through channel no.…”
Section: Validation Of the Model And Methodsmentioning
confidence: 99%
“…The present model with three thermal 13 couplings, accounting for the thermal capacity of the walls and heat conduction along the walls, is reduced to the model analysed in the work [10] Verifying calculations are carried out assuming that the system, initially at steady-state, undergoes an exponential rise of the inlet temperature of the fluid flowing through channel no. 1.…”
Section: Validation Of the Model And Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Bielski and Malinowski [21] presented a semi-analytical method and analytical method [22] to analyze the dynamic behaviour of parallel three-fluid heat exchanger with two thermal communications. Recently, they further set up the numerical model [23] that takes into account the thermal capacitance of the walls, the longitudinal heat conduction through the walls, and the conductive resistance across the walls to study the transient temperature response of the parallel three-fluid heat exchanger.…”
Section: Introductionmentioning