2021
DOI: 10.1039/d1ay00500f
|View full text |Cite
|
Sign up to set email alerts
|

A sensitive sensor based on molecularly imprinted polypyrrole on reduced graphene oxide modified glassy carbon electrode for nevirapine analysis

Abstract: A molecularly imprinted polymer (MIP) sensor was offered for nevirapine (NVP) analysis based on the electropolymerization of pyrrole (Py) on electrochemically reduced graphene oxide (ErGO) immobilized on a glassy carbon electrode (GCE).

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
5
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 40 publications
1
5
0
Order By: Relevance
“…The negative linear shift of E a p from 1.200 to 0.850 V with increasing pH was also observed as shown in Fig. 5B resulting in two Nernstian ranges [10,62,63] over pH 5-9 and 10-12 with slopes of 60.1 and 33.7 mV⋅decade − 1 , respectively (Fig. 5C and D).…”
Section: Effect Of Ph On the Electrochemical Behaviour Of Efv At Cuc/...supporting
confidence: 59%
“…The negative linear shift of E a p from 1.200 to 0.850 V with increasing pH was also observed as shown in Fig. 5B resulting in two Nernstian ranges [10,62,63] over pH 5-9 and 10-12 with slopes of 60.1 and 33.7 mV⋅decade − 1 , respectively (Fig. 5C and D).…”
Section: Effect Of Ph On the Electrochemical Behaviour Of Efv At Cuc/...supporting
confidence: 59%
“…The size distribution data also suggests that nanoparticles are formed and can be seen in the highlighted area. Further, the polymerization was confirmed by the rougher surface compared to silanized GO (Pour et al, 2021). The difference in morphology between silanized GO and MIP‐GO composite confirms the successful formation of the MIP layer on the surface of silanized GO.…”
Section: Resultsmentioning
confidence: 94%
“…The surface morphology of the synthesized material was examined by SEM. Figure 6a,b shows SEM images of silanized GO, and it shows the sheet‐like structure with lamella (Pour et al, 2021). However, after polymerization was done, Figure 6c,d clearly shows that silanized GO was covered with nanoparticles and microparticles ranging from 2 to 20 μm that verify the polymerization was successfully achieved on the surface of the silanized GO (Huang et al, 2019).…”
Section: Resultsmentioning
confidence: 99%
“…The electrolytes used for the experiment were 2.0 × 10 −3 mol l −1 NaOH with linearity over the range 0.01-0.14 ppm and a LOD of 3 nM were estimated from detection of 0.02 ppm after a 6 min accumulation. The proposed modified and unmodified sensors comparing their detection limits reported in literature for NVP detection are shown in Table II 33 showed a higher limit of detection and concentration range than other reported sensors followed by HgF. 44 Although the best results were found in HgF but due to its toxicity, this kind of sensor has been discontinued.…”
Section: Electrochemical Detection Of Nevirapine (Nvp)mentioning
confidence: 94%
“…GCE/MIP/ErGO.-Recently, a molecular imprinting polymer (MIP) sensor was fabricated by Pour and co-workers to develop the electro-polymerization of pyrrole (Py) on electrochemically reduced graphene oxide (ErGO) immobilized on a glassy carbon electrode (GCE) and successfully used for NVP analysis. 33 The NVP measurements were tested using DPV in an alkaline medium under optimized environment. The DPV signal of NVP increased linearly with concentration the range of 0.005 μM and 400 μM and was highly stable for an extended period.…”
Section: Electrochemical Detection Of Nevirapine (Nvp)mentioning
confidence: 99%