2013
DOI: 10.1007/s11051-013-2183-3
|View full text |Cite
|
Sign up to set email alerts
|

A settling tube to determine the terminal velocity and size distribution of fluidized nanoparticle agglomerates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
16
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 15 publications
(19 citation statements)
references
References 24 publications
3
16
0
Order By: Relevance
“…The size distribution of the fluidized agglomerates was experimentally determined from the images taken by the settling tube technique [29]. For all the powders, the agglomerate size varies between 76 µm and 462 µm, which is in good agreement with values found in literature using a high speed camera [10,11,13,21,22].…”
Section: Size Distributionsupporting
confidence: 82%
See 2 more Smart Citations
“…The size distribution of the fluidized agglomerates was experimentally determined from the images taken by the settling tube technique [29]. For all the powders, the agglomerate size varies between 76 µm and 462 µm, which is in good agreement with values found in literature using a high speed camera [10,11,13,21,22].…”
Section: Size Distributionsupporting
confidence: 82%
“…The settling tube is a black box with an opening at the top to catch falling agglomerates, and two openings on the side for agglomerate recording and tube cleaning purposes (Fig.1). A rigid borescope (Olympus R040-021-000-60 S5) and high speed camera (Phantom v9.1) system are used for the recordings, enabling a visible size range from 30 µm to 4 mm [29].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…They analyzed the shape and formation mechanism of agglomerates to reveal that most of the agglomerates have a branching structure with a well-defined center. De Martin et al proposed an in situ technique to determine continuously and accurately the agglomerate size of TiO 2 nanoparticles [6]. They found that the agglomerate size distribution is similar to the one for other nanoparticles whose averaged agglomerate diameter is 100 to 200 μm [5,[7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…Since agglomerates of nanoparticles which are formed during fluidization are very light and fragile in nature, agglomerate sampling techniques have recently received attention from researchers . However, there are some studies in which particle samples were physically removed from the bed and then were prepared for microphotograph examination.…”
Section: Methodsmentioning
confidence: 99%