2020
DOI: 10.1109/tpel.2019.2944688
|View full text |Cite
|
Sign up to set email alerts
|

A Si/SiC Hybrid Five-Level Active NPC Inverter With Improved Modulation Scheme

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
38
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 51 publications
(39 citation statements)
references
References 25 publications
0
38
0
1
Order By: Relevance
“…Both the analytical and experimental approaches provide the same results. As can be seen, in the inverter side the most stressed switches are Sy,21, Sy,22, while the least stressed switches are located in the middle leg Sy, 23,Sy,24. In the rectifier side, the most stressed and the least stressed power semiconductors are Dx, 21,Dx,22 and Sx,23,Sx,24, respectively. Based on the datasheet provided by the power semiconductor manufacturers, it has been possible to estimate the efficiency distribution of the proposed converters using an analytical approach and a simulation approach.…”
Section: Simulation Resultsmentioning
confidence: 96%
See 2 more Smart Citations
“…Both the analytical and experimental approaches provide the same results. As can be seen, in the inverter side the most stressed switches are Sy,21, Sy,22, while the least stressed switches are located in the middle leg Sy, 23,Sy,24. In the rectifier side, the most stressed and the least stressed power semiconductors are Dx, 21,Dx,22 and Sx,23,Sx,24, respectively. Based on the datasheet provided by the power semiconductor manufacturers, it has been possible to estimate the efficiency distribution of the proposed converters using an analytical approach and a simulation approach.…”
Section: Simulation Resultsmentioning
confidence: 96%
“…Furthermore, the weight and volume of the converter passive components are likely to be reduced [14][15][16][17], which is very appealing for several applications, where the overall size and weight of the electrical generating system needs to be minimized. Given the high number of benefits, more and more multilevel converter topologies are proposed in the literature [17][18][19][20][21]. It is understood that multilevel topology can act on the voltage stress of the power semiconductors, leaving their current ratings unchanged.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…As a result, a 5L ANPC full-bridge topology with a 4SiC/2Si hybrid scheme was proposed, as shown in Fig . 27 [99] . By employing the novel modulation scheme, some switching actions are added to decrease the conduction loss.…”
Section: Hybrid Applications Under 5l-anpcmentioning
confidence: 99%
“…Therefore, not being able to operate at high frequency, using SiC devices will not be so beneficial in cell 2. Recently, a hybrid Si/SiC 5L-ANPC inverter has been introduced to mitigate the overall losses while maintaining a compromise between the cost and efficiency [18] . However, the IGBTs and SiC MOSFETs are required to block the whole and half of the DC-bus voltage, respectively.…”
Section: Introduction mentioning