2022
DOI: 10.1016/j.conbuildmat.2022.127664
|View full text |Cite
|
Sign up to set email alerts
|

A silanized MCNT/TPU-based flexible strain sensor with high stretchability for deformation monitoring of elastomeric isolators for bridges

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 30 publications
0
5
0
Order By: Relevance
“…Figure 8B demonstrates the trend of the maximum GF and maximum monitoring range of the composites. The MWCNT‐NSD 5 /VMQ composites had the lowest maximum monitored strain (ε = 48%), and with increasing NSD content, the MWCNT‐NSD 20 /VMQ composites reached a range of monitored strains of ε = 180%, which satisfies the strain monitoring range of seismic isolation bearings 28 . In addition, the maximum resistance of the MWCNT‐NSD 5 /VMQ composite rises from (R/R0 = 127) to MWCNT‐NSD 15 /VMQ (R/R0 = 17,555), which indicates that the damage to the conductive network of the composites is more severe and contributes to the higher GF.…”
Section: Resultsmentioning
confidence: 63%
See 1 more Smart Citation
“…Figure 8B demonstrates the trend of the maximum GF and maximum monitoring range of the composites. The MWCNT‐NSD 5 /VMQ composites had the lowest maximum monitored strain (ε = 48%), and with increasing NSD content, the MWCNT‐NSD 20 /VMQ composites reached a range of monitored strains of ε = 180%, which satisfies the strain monitoring range of seismic isolation bearings 28 . In addition, the maximum resistance of the MWCNT‐NSD 5 /VMQ composite rises from (R/R0 = 127) to MWCNT‐NSD 15 /VMQ (R/R0 = 17,555), which indicates that the damage to the conductive network of the composites is more severe and contributes to the higher GF.…”
Section: Resultsmentioning
confidence: 63%
“…The MWCNT-NSD 5 /VMQ composites had the lowest maximum monitored strain (ε = 48%), and with increasing NSD content, the MWCNT-NSD 20 / VMQ composites reached a range of monitored strains of ε = 180%, which satisfies the strain monitoring range of seismic isolation bearings. 28 In addition, the maximum resistance of the MWCNT-NSD 5 /VMQ composite rises from (ΔR=R 0 = 127) to MWCNT-NSD 15 /VMQ (ΔR=R 0 = 17,555), which indicates that the damage to the conductive network of the composites is more severe and contributes to the higher GF. However, the maximum resistance of MWCNT-NSD 20 /VMQ composites decreases with a further increase in NSD content, which is attributed to the increase in the continuity between MWCNTs and NSD in the VMQ matrix, and the conductive network is more tightly packed, leading to a decrease in the maximum resistance of the composites.…”
Section: Strain Sensing Behaviors and Interface Effect Of Mwcnt-nsd/v...mentioning
confidence: 98%
“…The commercial silicone elastomer Ecoflex has a very low Young's modulus and is used mostly for ultrastretchable sensors [46][47][48]. Thermoplastic polyurethane (TPU) is also a common flexible matrix used for stretchable sensors due to its alternating hard and flexible segments that allow high durability and high filler content [49]. Meanwhile, for the wearable application, the biocompatibility of the materials with the human body is vital.…”
Section: Polymeric Substrates In Flexible Strain Sensorsmentioning
confidence: 99%
“…29,30 The presence of KH550 triggers the cross-linking entanglement between SBR and TPU, which reduces the formation opportunity of sulfur cross-linking between molecules to a large extent and therefore avoids the possible aggregation of SBR in the matrix. 31…”
Section: Ftir Spectramentioning
confidence: 99%