2020
DOI: 10.2478/macvetrev-2020-0014
|View full text |Cite
|
Sign up to set email alerts
|

A Simple and Rapid LC-MS/MS Method for Determination of Dexamethasone in Bovine Milk

Abstract: This study provides insight into the development and validation of the simple, rapid and sensitive method of Liquid Chromatography-Tandem Mass Spectrometry for determining the residues of dexamethasone in bovine milk. The maximum residue limit for dexamethasone in bovine milk is 0.3 ng/ml−1. Chromatographic separation was achieved on an Agilent Proshell 120 SB:C18 (2.7µm 100x3.0 mm) column. The bovine milk was extracted with ethyl acetate, and the evaporated elution was dissolved with hexane, water and methano… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(1 citation statement)
references
References 10 publications
0
1
0
Order By: Relevance
“…The newly developed method perfectly covers the regulatory recommended lower limit of quantification concentration as well as accurately measuring the peak concentration (LLOQ: ∼2 ng/ml and ULOQ: ∼600 ng/ml) than any other published methods. 814 Although there are few methods like Mei Zhang et al, 8 who have developed the LC-MS/MS method with 0.5–500 µg/L linearity range, and an analogous internal standard or A. Laura Nijstad et al, 10 who have developed the LC-MS/MS method with 1–500 ng/ml linearity range, however, the newly developed method is superior to these methods for the simple reason of its superior extraction process (protein precipitation vs. liquid–liquid extraction). Protein precipitation is known to have an inherent matrix effect, that is normally not seen in liquid–liquid extraction.…”
Section: Introductionmentioning
confidence: 99%
“…The newly developed method perfectly covers the regulatory recommended lower limit of quantification concentration as well as accurately measuring the peak concentration (LLOQ: ∼2 ng/ml and ULOQ: ∼600 ng/ml) than any other published methods. 814 Although there are few methods like Mei Zhang et al, 8 who have developed the LC-MS/MS method with 0.5–500 µg/L linearity range, and an analogous internal standard or A. Laura Nijstad et al, 10 who have developed the LC-MS/MS method with 1–500 ng/ml linearity range, however, the newly developed method is superior to these methods for the simple reason of its superior extraction process (protein precipitation vs. liquid–liquid extraction). Protein precipitation is known to have an inherent matrix effect, that is normally not seen in liquid–liquid extraction.…”
Section: Introductionmentioning
confidence: 99%