2012
DOI: 10.1007/s10967-012-1764-4
|View full text |Cite
|
Sign up to set email alerts
|

A simple and sensitive particle induced gamma-ray emission method for non-destructive quantification of lithium in lithium doped Nd2Ti2O7 ceramic sample

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2013
2013
2016
2016

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 13 publications
0
11
0
Order By: Relevance
“…The samples were collected at a depth ranging 5-30 cm by using normal auger method. The samples were dried below 60°C for 12 h. For determination of F, in soil samples, in situ current normalized PIGE methodology was adopted [19]. Fluorine standards were prepared by mixing homogenously varying amount of CaF 2 (30-50 mg) and constant amount of Li 2 CO 3 (*20 mg) in cellulose matrix.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The samples were collected at a depth ranging 5-30 cm by using normal auger method. The samples were dried below 60°C for 12 h. For determination of F, in soil samples, in situ current normalized PIGE methodology was adopted [19]. Fluorine standards were prepared by mixing homogenously varying amount of CaF 2 (30-50 mg) and constant amount of Li 2 CO 3 (*20 mg) in cellulose matrix.…”
Section: Methodsmentioning
confidence: 99%
“…For the determination of F in soil, we have standardized an in situ PIGE methodology for nondestructive determination of F in soil samples using 4 MeV proton beam from the Folded Tandem Ion Accelerator (FOTIA) located at BARC in Mumbai, India. Li was used as in situ current normalizer [19]. In situ current normalizer is the element which has high sensitivity towards PIGE and it should not be present in the sample of interest.…”
Section: Introductionmentioning
confidence: 99%
“…In PIGE experiments, sample pellets are made with graphite or cellulose as binder. 31,[34][35][36]39 Though their matrix comprises low Z elements (C for graphite and C, H, and O for cellulose), there are no γ-ray interferences from (p, p′γ) reactions of C and O at a 4 MeV proton beam. 31 Cellulose, used in the present work, was preferred compared to graphite for preparing pellets, as the current was not measured from the target.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…34,35 Calculated detection limits for selected samples are given in Table 6. The detection limit values are in the range of 0.3−1.9 mg kg −1 using 2125 keV of 11 B, and 0.3−2.6 mg kg −1 and 1.3−6.0 mg kg −1 using 429 and 718 keV of 10 B, respectively.…”
Section: ■ Experimental Detection Limits Of Boron By Pigementioning
confidence: 99%
See 1 more Smart Citation