2019
DOI: 10.1016/j.saa.2019.02.009
|View full text |Cite
|
Sign up to set email alerts
|

A simple benzimidazole styryl-based colorimetric chemosensor for dual sensing application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(5 citation statements)
references
References 69 publications
0
5
0
Order By: Relevance
“…Insignificant color change was observed for Ag + , Cu 2+ , Pb 2+ , Fe 2+ , and Fe 3+ ions that nevertheless showed weak fluorescence response. This notable color change of chemosensor 2CND with the addition of Sn 2+ was due to the dissociation of −OH protons and the inhibited photoinduced electron transfer (PET) mechanism which arose in 2CND –Sn 2+ complex . The deprotonated functional groups absorb light of a given wavelength in the visible region, which makes the color transformation (Figure ).…”
Section: Resultsmentioning
confidence: 99%
“…Insignificant color change was observed for Ag + , Cu 2+ , Pb 2+ , Fe 2+ , and Fe 3+ ions that nevertheless showed weak fluorescence response. This notable color change of chemosensor 2CND with the addition of Sn 2+ was due to the dissociation of −OH protons and the inhibited photoinduced electron transfer (PET) mechanism which arose in 2CND –Sn 2+ complex . The deprotonated functional groups absorb light of a given wavelength in the visible region, which makes the color transformation (Figure ).…”
Section: Resultsmentioning
confidence: 99%
“…In addition, the deprotonated groups absorb the suitable wavelength of light in the visible region, which induces the color change. The other reason could be that the charge transfer occurred between the 2HPN –Fe 2+ complex via π conjugation . The process of color change between 2HPN and Fe 2+ occurred within 3 min, and the solution pH was measured as ∼6.5–7.0 (for Fe 2+ , pH ∼6.7).…”
Section: Resultsmentioning
confidence: 99%
“…The other reason could be that the charge transfer occurred between the 2HPN−Fe 2+ complex via π conjugation. 41 The process of color change between 2HPN and Fe 2+ occurred within 3 min, and the solution pH was measured as ∼6.5−7.0 (for Fe 2+ , pH ∼6.7).…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…However, in the literature, the detection studies of these anions do not typically provide a specific value for the LOQ. Regarding the estimated LOD value, it is worth noting that the LOQ values for SO 4 2− and HSO 4 − anions showed values below the maximum levels allowed by the United States Environmental Protection Agency [43] and the World Health Organization (WHO) [44], which are 500 mg•L −1 and 250 mg•L −1 , respectively, whereas there is no established standard for CO 3 2− and HCO 3 − set by regulatory agencies. Thus, the values determined in this study for the quantification of the target anions are well below the established maximum concentrations allowed.…”
Section: Fluorescent Detection Of Anions Using Cdte-cya Qdsmentioning
confidence: 99%