2015
DOI: 10.3938/jkps.67.254
|View full text |Cite
|
Sign up to set email alerts
|

A simple DVH generation technique for various radiotherapy treatment planning systems for an independent information system

Abstract: In recent years, the use of a picture archiving and communication system (PACS) for radiation therapy has become the norm in hospital environment and has suggested for collecting data and management from different treatment planning systems (TPSs) with the Digital Imaging and Communication in Medicine (DICOM) objects. However, some TPS does not provide the dosevolume histogram (DVH) exportation with text or other format. In addition, plan review systems for various TPSs often allow DVH recalculation with diffe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2016
2016
2017
2017

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 19 publications
0
2
0
Order By: Relevance
“…Adjusting the dose grid resolution in CERR to the same value of TPS could decrease this difference. Also, the structure’s volume calculation of TPSs and CERR affected the DVH accuracy, especially in the small volume [ 9 ]. Therefore, a larger difference between Oncentra and CERR was observed when D 2cc of OARs was considered.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Adjusting the dose grid resolution in CERR to the same value of TPS could decrease this difference. Also, the structure’s volume calculation of TPSs and CERR affected the DVH accuracy, especially in the small volume [ 9 ]. Therefore, a larger difference between Oncentra and CERR was observed when D 2cc of OARs was considered.…”
Section: Discussionmentioning
confidence: 99%
“…The SWAN system can decrease the uncertainty from a longitudinal direction, which includes the dose in half image-slice regions outside the superior and the inferior of each volume. However, the interpolation uncertainty from the contour boundary remained in CERR and TPS as it depends on the voxel resolution, DVH computation algorithm, and the partial voxel in the boundary of the contour polygon [ 9 , 10 ]. EQD 2 VH is suitable for treatment planning evaluation, determination, and selection of the best treatment plan when different doses per fraction are given [ 11 ].…”
Section: Discussionmentioning
confidence: 99%