1991
DOI: 10.3208/sandf1972.31.169
|View full text |Cite
|
Sign up to set email alerts
|

A Simple Gauge for Local Small Strain Measurements in the Laboratory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
112
0

Year Published

2002
2002
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 338 publications
(116 citation statements)
references
References 10 publications
4
112
0
Order By: Relevance
“…Note that the Gd value was normalized by the void ratio function, f(e), in Eq. (6). Decreases in the Gd values during liquefaction were observed with the reduction of the eŠective stress level on all the specimens.…”
Section: Applicability Of Reconstituted Sample For In-situ Frozen Samplementioning
confidence: 92%
See 1 more Smart Citation
“…Note that the Gd value was normalized by the void ratio function, f(e), in Eq. (6). Decreases in the Gd values during liquefaction were observed with the reduction of the eŠective stress level on all the specimens.…”
Section: Applicability Of Reconstituted Sample For In-situ Frozen Samplementioning
confidence: 92%
“…Refer to Kiyota et al (2009) for the details of the apparatus and the transducers employed. The vertical static Young's modulus, Ev, was evaluated from the small cyclic stress-strain relationships with a double amplitude vertical strain of approximately 0.002z, which were measured with a pair of local deformation transducers (LDTs, Goto et al, 1991). To calculate the static shear moduli, Gs * (denoted as Gs), from the Ev, Eq.…”
Section: Test Apparatusmentioning
confidence: 99%
“…The tests were carried out under monotonic displacement control, at a rate of 0.1 mm/min (slower than the value recommended by ASTM D1633 (2007)), in order to perform small unload-reload cycles in some of the specimens. Local deformation transducers (LDTs) were used for increased strain measurement accuracy (Goto et al, 1991;Hayano et al, 1997).…”
Section: Specimen Fabrication and Testingmentioning
confidence: 99%
“…As shown in Photo 1, in the case of passive control tests, axial strain (e1) was measured with three pairs of vertical local deformation transducers (V-LDTs) (Goto et al, 1991) in addition to external measurement with a linear variable diŠerential transducer (LVDT). In both active and passive control tests, one of the two lateral strains (e2) was measured by another three pairs of horizontal local deformation transducers (H-LDTs).…”
Section: Large Scale True Triaxial Apparatusmentioning
confidence: 99%