1985
DOI: 10.1088/0022-3735/18/5/010
|View full text |Cite
|
Sign up to set email alerts
|

A simple method for the determination of the hysteresis parameters of hard magnetic materials by pulsed fields

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

1986
1986
2015
2015

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…The resonance is stronger with higher pulsed fields, resulting in the lower signal-to-noise ratio (SNR). This problem was already pointed out by Likhite et al (1985) who was forced to limit the pulse peak <0.6 T due to the imbalance of pick-up coil caused by "ringing" of the coil system. In the same way, because a slight failure of the coil compensation contributes to greater reduction of the SNR, we found that the maximum peak of a pulse was set to 0.7 T in this study.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The resonance is stronger with higher pulsed fields, resulting in the lower signal-to-noise ratio (SNR). This problem was already pointed out by Likhite et al (1985) who was forced to limit the pulse peak <0.6 T due to the imbalance of pick-up coil caused by "ringing" of the coil system. In the same way, because a slight failure of the coil compensation contributes to greater reduction of the SNR, we found that the maximum peak of a pulse was set to 0.7 T in this study.…”
Section: Methodsmentioning
confidence: 99%
“…The IRM unmixing analysis has become a conventional tool for the quantitative characterization of magnetic minerals (Kruiver et al 2001;Heslop et al 2002;Egli 2004;Abrajevitch and Kodama 2011). However, the measurement of dynamic magnetizations in pulsed fields has been paid little attention except the pioneering work by Radhakrishnamurthy and Likhite (1987) who obtained hysteresis parameters from a set of synthetic and basalt samples using a laboratory-made PFM system (Likhite et al 1985). They compared the results both at room and low temperature (77 K), suggesting that the latter provided a better estimate of the composition and domain state.…”
Section: Introductionmentioning
confidence: 99%
“…Pulse field (PF) technique [8] has been used for measuring the room temperature magnetization (M s ) of the transformer oil-based Co 1Àx Zn x Fe 2 O 4 with x varying from 0 to 0.7 FF fluid samples in a field of 400 kA/m. It has been restricted to measurement of bulk solid samples.…”
Section: Magnetic Measurementsmentioning
confidence: 99%