2016
DOI: 10.1109/tpel.2015.2420568
|View full text |Cite
|
Sign up to set email alerts
|

A Single-Sensor-Based MPPT Controller for Wind-Driven Induction Generators Supplying DC Microgrid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
47
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 129 publications
(47 citation statements)
references
References 42 publications
0
47
0
Order By: Relevance
“…Similarly, the mechanical power P m * shown in (8) can be transformed to the function of slip s slip Figure 9a illustrates the mechanical power and air-gap power with respect to slip according to (11) and (13). As shown in the figure, there are three intersection points when the infinite voltage is 1.0 p.u., and only the middle operating point is unstable.…”
Section: Abnormally Low Voltage Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…Similarly, the mechanical power P m * shown in (8) can be transformed to the function of slip s slip Figure 9a illustrates the mechanical power and air-gap power with respect to slip according to (11) and (13). As shown in the figure, there are three intersection points when the infinite voltage is 1.0 p.u., and only the middle operating point is unstable.…”
Section: Abnormally Low Voltage Analysismentioning
confidence: 99%
“…However, microgrids can be subjected to a high penetration level of induction motor loads, and the highly nonlinear IM loads dynamics may challenge the stability of microgrids [12]. Besides, although the newly installed wind turbines are connected to grid through power electronics and researches are mainly focus on novel control strategy of these machines [13,14], a certain number of Type 1 induction generators are still operating in conventional wind farms [15]. As a result, the dynamic behavior of induction machines has a significant impact on power system stability.…”
Section: Introductionmentioning
confidence: 99%
“…In [10] Advanced HCS is proposed which stores the data given by HCS algorithm in an intelligent memory and uses these data to find the reference speed instead of searching again and this algorithm is generically called Search-Remember-Reuse algorithm. In [18] P & O is used for MPPT for WECS supplying DC micro-grid. The Optimum Relation Based (ORB) algorithm uses relation between system parameters to estimate the reference speed.…”
Section: Introductionmentioning
confidence: 99%
“…Wind energy as an important type of the available renewable energies has been permanently attractive for man, and has been even utilized by some old devices such as windmills for centuries. A WECS essentially consists of a wind turbine and an electric generator [2], although for an efficient WECS supplied to a DC load, an AC/DC converter including a three-phase rectifier, and a MPPT controller are also necessary [3].…”
Section: Introductionmentioning
confidence: 99%