2018
DOI: 10.1088/1361-6560/aa9b47
|View full text |Cite
|
Sign up to set email alerts
|

A singular value decomposition linear programming (SVDLP) optimization technique for circular cone based robotic radiotherapy

Abstract: With robot-controlled linac positioning, robotic radiotherapy systems such as CyberKnife significantly increase freedom of radiation beam placement, but also impose more challenges on treatment plan optimization. The resampling mechanism in the vendor-supplied treatment planning system (MultiPlan) cannot fully explore the increased beam direction search space. Besides, a sparse treatment plan (using fewer beams) is desired to improve treatment efficiency. This study proposes a singular value decomposition line… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 37 publications
(30 reference statements)
0
4
0
Order By: Relevance
“…This method takes full advantage of the treatment space but also means greater computational cost. The second scenario was adopted in our previous work [ 8 ] with a novel technique for beam initialization. The mechanism simulates the process of moving the equivalent dose taper to cover the entire target volume.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…This method takes full advantage of the treatment space but also means greater computational cost. The second scenario was adopted in our previous work [ 8 ] with a novel technique for beam initialization. The mechanism simulates the process of moving the equivalent dose taper to cover the entire target volume.…”
Section: Methodsmentioning
confidence: 99%
“…The beam initialization was implemented in C++, and dose was calculated using ray-tracing method on GPU. Plans evaluation was performed on an in-house platform, which was developed and validated in our previous study [ 8 , 20 ]. The MLP plans were also imported to the platform, and all the following mentioned plan evaluation indices were calculated under the same resolution (2 mm × 2 mm × 2 mm) with AD-S plans.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The top three subspecialties are radiation imaging (218 papers), radiation therapy (70 papers), and magnetic resonance (42 papers). Within the subspecialty of radiation therapy, the number of publications are 15 papers in the field of clinical implementation [41][42][43][44][45][46][47][48][49][50][51][52][53][54][55], 11 papers in the field of plan optimization [56][57][58][59][60][61][62][63][64][65][66], 14 papers in the field of plan evaluation [67][68][69][70][71][72][73][74][75][76][77][78][79][80], and 12 papers in the field of quality assurance [81][82][83][84][85][86][87][88]…”
Section: Scientific Researchmentioning
confidence: 99%