A Solid‐State Reference Electrode Based on a Self‐Referencing Pulstrode

Abstract: The design of solid-state reference electrodes without liquid junction is of great importance to allow for miniature and costeffective electrochemical sensors in environmental and biomedical applications. To address this, we propose here a pulse control protocol using an Ag/AgI element as reliable solid-state reference electrode. It involves the local release of iodide by a cathodic current that is immediately followed by an electromotive force (EMF) measurement that serves as the reference potential. The reca… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
23
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 27 publications
(23 citation statements)
references
References 41 publications
0
23
0
Order By: Relevance
“…Currently, polymer-based [92][93][94], ionic liquid-junction [95][96][97], and lipophilic salts modified-polymer [98,99] are the main solid-state REs. Recently, a solid-state RE of Ag/AgI based on a self-referencing pulstrode offers a new strategy [100]. 3The leaking of ISM components is another issue that should be emphasized.…”
Section: Discussionmentioning
confidence: 99%
“…Currently, polymer-based [92][93][94], ionic liquid-junction [95][96][97], and lipophilic salts modified-polymer [98,99] are the main solid-state REs. Recently, a solid-state RE of Ag/AgI based on a self-referencing pulstrode offers a new strategy [100]. 3The leaking of ISM components is another issue that should be emphasized.…”
Section: Discussionmentioning
confidence: 99%
“…Bakker’s group proposed a novel concept of a solid-state reference electrode using a Ag/AgI element . The concept is based on the local release of iodide by a cathodic current that is immediately followed by an electromotive force measurement that serves as the reference potential (see Figure ).…”
Section: Reference Electrodesmentioning
confidence: 99%
“…Working principle of a pulsed self-referencing Ag/AgI electrode . The protocol includes four steps: (1) recording of the initial open-circuit potential; (2) local release of iodide ions by applying a cathodic current pulse; (3) recording the EMF at the open circuit (at the point indicated as the red circle); (4) recapture of the released iodide ions by applying a constant potential pulse based on the initial OCP value.…”
Section: Reference Electrodesmentioning
confidence: 99%
See 1 more Smart Citation
“…Thewhole genetic circuit is operated under as imple Boolean logic design principle.T o evaluate the applicability of the integrated multi-function circuit, we implemented this molecular network abstraction into ab ioanalytical system operating on an electrochemical interface,w hich serves as as imple and cost-effective transduction system, capable of rapidly curating molecular information and transducing into data. [3] Bioanalytical strategies have been extensively developed toward better sensitivity,s implicity and selectivity, [4] while valid strategies can be further integrated into aportable,costeffective,r apid transduction platform for an ideal point-ofcare system. So far, ah igh-resolution molecular analytical strategy,capable of differentiating infinitesimal concentration variation, which is essential to understand the critical threshold limit of biomolecules,has not been realized with asimple biosensing system.…”
Section: Introductionmentioning
confidence: 99%