2014
DOI: 10.2528/pier14042708
|View full text |Cite
|
Sign up to set email alerts
|

A STED MICROSCOPE DESIGNED FOR ROUTINE BIOMEDICAL APPLICATIONS (Invited Paper)

Abstract: Abstract-We present a multi-color STED fluorescence microscope providing far-field optical resolution down to 20 nm for biomedical research. The optical design comprises fiber lasers, beam scanners, and a set of active and passive polarizing elements that cooperatively yield an optically robust system for routinely imaging samples at subdiffraction length scales.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
57
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
8
1

Relationship

5
4

Authors

Journals

citations
Cited by 46 publications
(60 citation statements)
references
References 26 publications
3
57
0
Order By: Relevance
“…This clearly demonstrates that the choice of markers in relation to the detection windows plays a crucial role. The number of distinguishable markers could be further increased by combining the present hyperSTED setup with other means of discrimination, for example excitation multiplexing21, fluorescence lifetime imaging2223 or photostability18, as previously reported. This is feasible without changes to the hardware, keeping the setup simple and stable.…”
Section: Discussionmentioning
confidence: 79%
See 1 more Smart Citation
“…This clearly demonstrates that the choice of markers in relation to the detection windows plays a crucial role. The number of distinguishable markers could be further increased by combining the present hyperSTED setup with other means of discrimination, for example excitation multiplexing21, fluorescence lifetime imaging2223 or photostability18, as previously reported. This is feasible without changes to the hardware, keeping the setup simple and stable.…”
Section: Discussionmentioning
confidence: 79%
“…Evaluating the promise of the hyperSTED approach as presented here, simulations20 indicate that six-colour separation of Abberior Star600, Atto594, DyLight633, Abberior Star635P, KK1441 and CF680R should be possible when adding the lifetime information from ratios of signals in two time gates22, if the assumed spectra and lifetimes of these dyes are as stated in Table 1. Note that for such a sample only one excitation wavelength of 612 nm and a single STED beam would be required.…”
Section: Discussionmentioning
confidence: 98%
“…Three different microscope setups have been used for the study: Laser Induced Fluorescence (LIF) microscopy (3.1) [10], Raman microscopy (3.2) [11] and Coherent Anti-Stokes Raman Scattering (CARS) microscopy (3.3) [12]. Various hydrophilic and hydrophobic intraocular lens materials were studied (3.4).…”
Section: Methodsmentioning
confidence: 99%
“…At present, however, simultaneous recordings of more than two fluorophore species still require complex setups and/or analysis algorithms34. Here, we utilize a pulsed fibre laser emitting at 620 nm as the STED light source and demonstrate its versatility in a novel three-colour STED microscopy scheme.…”
mentioning
confidence: 99%