2021
DOI: 10.1007/s40998-021-00414-z
|View full text |Cite
|
Sign up to set email alerts
|

A Step-by-Step Design Procedure of a Robust Control Design for Grid-Connected Inverter by LCL Filter in a Weak and Harmonically Distorted Grid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1
1

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 41 publications
0
4
0
Order By: Relevance
“…The two main active damping methods are single and multi-loop damping methods. Each of these loops includes the capacitor voltage loop (15), the capacitor current loop (16)(17)(18), and other loops. It should be noted that single-loop control strategies are advantageous because they are simple and perform satisfactorily due to the absence of supplementary measurement methods or passive damping measures.…”
Section: It Is Possible To Use Several Mppt Techniques Including Pert...mentioning
confidence: 99%
“…The two main active damping methods are single and multi-loop damping methods. Each of these loops includes the capacitor voltage loop (15), the capacitor current loop (16)(17)(18), and other loops. It should be noted that single-loop control strategies are advantageous because they are simple and perform satisfactorily due to the absence of supplementary measurement methods or passive damping measures.…”
Section: It Is Possible To Use Several Mppt Techniques Including Pert...mentioning
confidence: 99%
“…Also, by replacing ( 9) and ( 13) in (14), the current injected into the grid based on CVTF by applying a component proportional to the reference current i ref (s) and a component proportional to the grid voltage disturbance v g (s) can be obtained as follows:…”
Section: Cvtfmentioning
confidence: 99%
“…The use of resonance attenuation methods is necessary to ensure the stability of the LCL-based gridtied systems. 12 In general, resonance damping methods arising from LCL filters are divided into two categories: active damping methods 13,14 and passive damping methods. 15 Active damping methods are more favored due to their lower power losses, efficiency, and greater flexibility compared to passive damping methods.…”
Section: Introductionmentioning
confidence: 99%
“…where i g , i ref , and v g are the RMS values. Considering | T o (j2πf o )| ≫ 1, E A can be expressed as (34).…”
Section: Steady-state Errormentioning
confidence: 99%
“…However, system performance may be impaired in weak networks. In the study by Hosseinpour et al, 34 a grid‐connected battery system by considering the grid voltage feed‐forward loop and eliminating delays is investigated. This method can inject high‐quality current into the low‐voltage network.…”
Section: Introductionmentioning
confidence: 99%