A stepped Mach-Zehnder interferometric humidity sensor based on lateral offset fusion splicing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…151 When operated at 1558 nm, the sensitivity is highest (0.14 dB/% RH), and the sensor has a response time of 1 s. Without the gelatin coating, a similar Mach−Zehnder interferometer based RH sensor only has a sensitivity of −0.0487 dB/% RH. 152 A mesoporous composite film made from poly(allylamine hydrochloride) (PAH) and silica nanoparticles was deposited on an optical fiber and formed a FOCS for humidity. 153 The sensing film behaved like a Fabry−Perot cavity, the absorption of water changed the optical thickness and resulted in changes in reflection.…”
Section: Analytical Chemistrymentioning
confidence: 99%
See 1 more Smart Citation
“…151 When operated at 1558 nm, the sensitivity is highest (0.14 dB/% RH), and the sensor has a response time of 1 s. Without the gelatin coating, a similar Mach−Zehnder interferometer based RH sensor only has a sensitivity of −0.0487 dB/% RH. 152 A mesoporous composite film made from poly(allylamine hydrochloride) (PAH) and silica nanoparticles was deposited on an optical fiber and formed a FOCS for humidity. 153 The sensing film behaved like a Fabry−Perot cavity, the absorption of water changed the optical thickness and resulted in changes in reflection.…”
Section: Analytical Chemistrymentioning
confidence: 99%
“…A single-mode-side polished multimode/single-mode fiber structure was coated with gelatin and used as a FOCS for RH . When operated at 1558 nm, the sensitivity is highest (0.14 dB/% RH), and the sensor has a response time of 1 s. Without the gelatin coating, a similar Mach–Zehnder interferometer based RH sensor only has a sensitivity of −0.0487 dB/% RH . A mesoporous composite film made from poly­(allylamine hydrochloride) (PAH) and silica nanoparticles was deposited on an optical fiber and formed a FOCS for humidity .…”
Section: Sensors For Humidity and Water Fractionmentioning
confidence: 99%
“…The spectral response of MMZI with variable fringe widths shows higher sensitivity than that of the wavelength spectrum with uniform free spectral range (FSR) [11]. With regard to the tapered fiber, recently, diverse designs of inline MZI have been reported [12] with a wide variety of applications, which include the gain equalization of amplified spontaneous emission (ASE) response of an erbium-doped fiber amplifier (EDFA) [13], multi-wavelength laser [14][15][16][17][18][19][20], all-optical switching [21], wearable respiration monitoring [22], detection of ammonia [23], detection of uric acid [24], hydrogen sulfide gas [25], sensing of refractive index , curvature [52][53][54][55][56][57][58][59], temperature [60][61][62][63][64][65][66][67], strain [68][69][70][71], humidity [72][73][74][75], pressure [76,77], magnetic field [78][79][80], DC…”
Section: Introductionmentioning
confidence: 99%