Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Transjugular intrahepatic portosystemic shunt (TIPS) is a widely used surgery for portal hypertensive patients, whose potential postoperative complications are closely related to the hemodynamic condition of the portal venous system. The selection of shunt position in the surgery may affect the postoperative hemodynamics; however, it is difficult for clinical studies to investigate the influence. Therefore, this study aims to employ the computational model simulating TIPS to compare the hemodynamic differences resulting from different shunt positions, and also to investigate the influences of different geometrical model simplification strategies used in the TIPS simulation. For this purpose, the clinical data of two representative patients were retrospectively collected, based on which, the computational hemodynamic models of the portal venous systems after TIPS were constructed, incorporating three typical shunt positions (i.e. shunt at the left/main/right portal vein) and three types of geometrical model simplification. Results showed that among the models with different shunt positions, the area-averaged flow velocity magnitudes in the shunts were very similar, while the model with shunt at the main portal vein showed the lowest postoperative portal pressure and the smallest area of high wall shear stress near the portal venous bifurcation. Among the models using different geometrical model simplification strategies, the simulated blood pressures at the main portal veins were very similar, but showed marked differences near the shunt inlets. Moreover, the area-averaged flow velocity magnitudes in the shunts were almost the same, while the velocity distributions differed a lot, leading to the different spatial distributions of wall shear stress near the portal venous bifurcations and shunt walls. These results on one hand suggested that placing the shunt at the main portal vein is more beneficial for the patient; on the other hand, they proved the feasibility of utilizing simplified model to save computational cost without losing the accuracy when the pressure at the main portal vein is mainly focused on. These findings would assist clinical decision-making and promote more accurate and efficient TIPS simulations.
Transjugular intrahepatic portosystemic shunt (TIPS) is a widely used surgery for portal hypertensive patients, whose potential postoperative complications are closely related to the hemodynamic condition of the portal venous system. The selection of shunt position in the surgery may affect the postoperative hemodynamics; however, it is difficult for clinical studies to investigate the influence. Therefore, this study aims to employ the computational model simulating TIPS to compare the hemodynamic differences resulting from different shunt positions, and also to investigate the influences of different geometrical model simplification strategies used in the TIPS simulation. For this purpose, the clinical data of two representative patients were retrospectively collected, based on which, the computational hemodynamic models of the portal venous systems after TIPS were constructed, incorporating three typical shunt positions (i.e. shunt at the left/main/right portal vein) and three types of geometrical model simplification. Results showed that among the models with different shunt positions, the area-averaged flow velocity magnitudes in the shunts were very similar, while the model with shunt at the main portal vein showed the lowest postoperative portal pressure and the smallest area of high wall shear stress near the portal venous bifurcation. Among the models using different geometrical model simplification strategies, the simulated blood pressures at the main portal veins were very similar, but showed marked differences near the shunt inlets. Moreover, the area-averaged flow velocity magnitudes in the shunts were almost the same, while the velocity distributions differed a lot, leading to the different spatial distributions of wall shear stress near the portal venous bifurcations and shunt walls. These results on one hand suggested that placing the shunt at the main portal vein is more beneficial for the patient; on the other hand, they proved the feasibility of utilizing simplified model to save computational cost without losing the accuracy when the pressure at the main portal vein is mainly focused on. These findings would assist clinical decision-making and promote more accurate and efficient TIPS simulations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.