2022
DOI: 10.1016/j.est.2022.104458
|View full text |Cite
|
Sign up to set email alerts
|

A stretchable, high-voltage and biobased microsupercapacitor using laser induced graphene/MnOx electrodes on cotton cloth

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
13
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 20 publications
(13 citation statements)
references
References 55 publications
0
13
0
Order By: Relevance
“…[ 158 ] A combination of CNDs and GO leads to drastically improved electrochemical properties. [ 159 ] In addition, stretchable micro‐supercapacitors, fabricated via laser patterning of MnOx/cotton cloth microelectrodes have also been reported, [ 173 ] with a rated voltage of 60 V can light up 20 LEDs for more than 30 s.…”
Section: Laser‐carbonization – Reviewmentioning
confidence: 99%
“…[ 158 ] A combination of CNDs and GO leads to drastically improved electrochemical properties. [ 159 ] In addition, stretchable micro‐supercapacitors, fabricated via laser patterning of MnOx/cotton cloth microelectrodes have also been reported, [ 173 ] with a rated voltage of 60 V can light up 20 LEDs for more than 30 s.…”
Section: Laser‐carbonization – Reviewmentioning
confidence: 99%
“…In an air atmosphere, precarbonization of cotton cloth was carried out in muffle furnace at 300 °C for 2 h. The obtained carbonized cloth was placed in a plastic mold for PDMS (Sylgard 184, Dow Corning, mixing ratio 10:1) casting as previously proposed for other LIG‐based materials. [ 56 ] Air was evacuated from liquid PDMS to allow full infiltration of the viscous elastomer into carbonized cloth, then the PDMS was crosslinked at 80 °C for 3, 4, 5, 6, 7, 8, and 9 min in a convection oven, respectively. The carbonized cloth was placed on the precured PDMS and sank inside with tunable depth because the viscosity of liquid PDMS was controlled by precuring time.…”
Section: Methodsmentioning
confidence: 99%
“…27,38,39 As the second category, flexible substrates (polymer, paper, and textile cloth) have been incorporated into foldable and wearable devices. [40][41][42][43] To evaluate the electrochemical performance of PMSCs, conventional test parameters should be finely tuned based on the planar configuration. The measurement units need to be changed to the area and volume of PMSCs instead of the mass of active materials.…”
Section: Configuration and Energy Storage Mechanism Of Pmscsmentioning
confidence: 99%