INTELEC 2009 - 31st International Telecommunications Energy Conference 2009
DOI: 10.1109/intlec.2009.5351768
|View full text |Cite
|
Sign up to set email alerts
|

A study of the safety of the DC 400 V distribution system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
7
3

Relationship

2
8

Authors

Journals

citations
Cited by 31 publications
(16 citation statements)
references
References 1 publication
0
10
0
Order By: Relevance
“…Switchgear including circuit breakers, fuses, etc., and proper grounding methods are required to make the DC system safer. Comprehensive research has been conducted and papers have been published on improving the safety in DC distribution systems [37][38][39][40]; different papers have studied protection against electric shock related to DC generating devices such as photovoltaic generators from the perspective of personal safety [41,42]. Moreover, higher DC voltage levels would result in leakage currents in the system that can cause corrosion of the underground equipment, transformer saturation, and faulty operation of protective equipment [43].…”
Section: Safety and Protectionmentioning
confidence: 99%
“…Switchgear including circuit breakers, fuses, etc., and proper grounding methods are required to make the DC system safer. Comprehensive research has been conducted and papers have been published on improving the safety in DC distribution systems [37][38][39][40]; different papers have studied protection against electric shock related to DC generating devices such as photovoltaic generators from the perspective of personal safety [41,42]. Moreover, higher DC voltage levels would result in leakage currents in the system that can cause corrosion of the underground equipment, transformer saturation, and faulty operation of protective equipment [43].…”
Section: Safety and Protectionmentioning
confidence: 99%
“…To determine currents for safe operation, Dalziel theory [12], Koeppens theory [13] and IEC standards are commonly used. As the IEC standards are the most conservative among these we will consider them in this discussion.…”
Section: Safetymentioning
confidence: 99%
“…on the same safety level as ordinary industrial electrical equipment or home electrical appliances. To reduce the risk of electrical shock, it is important that the voltage relative to ground not be large, as is also proposed in [7].…”
Section: A Prevention Of Electrical Shock and Malfunction And Securmentioning
confidence: 99%