2020
DOI: 10.1134/s1063780x2001016x
|View full text |Cite
|
Sign up to set email alerts
|

A Study of the Ultraviolet Radiation of Hybrid X-Pinches

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
13
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(13 citation statements)
references
References 19 publications
0
13
0
Order By: Relevance
“…In contrast to our previous experiments [14,15], the used diffraction grating (3, figure 1) had an extremely large slit length (2 cm), inside and along which there are free-standing gold bars. To visualize the spectra, a quadrant MCP radiation recorder was used (4, figure 1), the working field of which was separated into four sectors, which allowed one to obtain up to four time-separated consecutive frames of the source image (6, figure 1).…”
Section: Description Of the Experiments And Diagnosticsmentioning
confidence: 77%
See 3 more Smart Citations
“…In contrast to our previous experiments [14,15], the used diffraction grating (3, figure 1) had an extremely large slit length (2 cm), inside and along which there are free-standing gold bars. To visualize the spectra, a quadrant MCP radiation recorder was used (4, figure 1), the working field of which was separated into four sectors, which allowed one to obtain up to four time-separated consecutive frames of the source image (6, figure 1).…”
Section: Description Of the Experiments And Diagnosticsmentioning
confidence: 77%
“…In the past a number of publications reported that loads made of flat or cylindrical foils, composed of different materials and different sizes, were exploded with pulse high-current generators for the purpose of various applications [1][2][3][4][5][6][7][8][9][10][11][12]. Under the 1000 Å), as well as soft x-ray (SXR) radiation (2 Å < λ < 100 Å) [13][14][15]. It is obvious that during the explosion of foils, we should also expect the presence of radiation of this range, which can be used to study the processes occurring in the foil load when a powerful current pulse passes through it.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…At the same time, data on polymer ablation under such extreme environment are practically absent in the literature. Besides, such studies are further complicated by the complexity of the radiation sources [ 19 , 20 , 21 , 22 ].…”
Section: Introductionmentioning
confidence: 99%