In this paper, we analyze indoor visible light communication environment based on LightTools. If the environments for VLC are too various, it is not easy to analyze the VLC environment using mathematical techniques. To overcome this problem, we use LightTools program for the analysis of various VLC environment.We use the SINR(Signal-to-Interference and Noise Ratio) as a performance measure and compared it with the theoretical values. From simulation results, we notice that the theoretical and the LightTools results show similar tendency with a certain margin. Therefore, it will be possible to utilize the proposed scheme in analyzing lots of variable VLC environments.