2022
DOI: 10.3390/en15030731
|View full text |Cite
|
Sign up to set email alerts
|

A Study on Control Strategy for Air Conditioning of Western Exposed Rooms in Subtropical Region

Abstract: Recently, energy saving has been a major issue in all aspects. In buildings, air conditioning is one major part of power consumption. In this study, we examined the effect of an intermittent control strategy for air conditioning on energy saving in western-exposed rooms under subtropical weather conditions. The strategy applied periodic deactivation and reactivation to the air conditioners. Room temperatures, power consumption, and readings from sensors of air conditioners of two identical rooms were monitored… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 14 publications
0
3
0
Order By: Relevance
“…The objective of this study is to use SPINLab [18,19] as an experimental platform to observe the thermal insulation performance of clear glass with windows films after changing some testing parameters. The parameter items include clear glass (OG), heat-absorbing film, reflective film, and building orientation (east, south, west, and northwest).…”
Section: Experimental Equipment and Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The objective of this study is to use SPINLab [18,19] as an experimental platform to observe the thermal insulation performance of clear glass with windows films after changing some testing parameters. The parameter items include clear glass (OG), heat-absorbing film, reflective film, and building orientation (east, south, west, and northwest).…”
Section: Experimental Equipment and Methodsmentioning
confidence: 99%
“…The temperature and humidity sensors are suspended 1.6 m above the ground. The human heat dissipation heat load data indoors was referred to in several references [18][19][20][21][22]. This study simulated that two people are using two computers in each room.…”
Section: Experimental Equipment and Methodsmentioning
confidence: 99%
“…If the temperature difference between inside room and outside (in atmosphere) is more, the HVAC unit will consume more electricity to cool the inside room air up to the desired thermostat setting. It has been observed by several scholars [14][15][16][17] that keeping thermostat setting lower to cool the space rapidly is leading to more electricity consumption without achieving the desired goal.…”
Section: Description Of Hvac Unitmentioning