A study on self-terminating behavior of sodium–concrete reaction

Abstract: A sodium-concrete reaction (SCR) is one of the important phenomena to cause the structural concrete ablation and the release of hydrogen (H 2) gas in the sodium (Na) leak accident. In this study, the long-time SCR test had been carried out to investigate the self-termination mechanism under the condition to keep the temperature of Na on the concrete more than the reaction threshold temperature during 24 hours. The test results showed the SCR terminated by itself even if enough amount of Na remained on the conc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(11 citation statements)
references
References 15 publications
0
11
0
Order By: Relevance
“…d 0 , t 0 , and k are fitting parameters defining the maximum concrete ablation depth, the start time, and the time constant, respectively, and d is the concrete ablation depth at the current time t. From the approximation curve in I-8M experiment, d 0 was determined as 0.09 m. This value almost matched the final concrete ablation depth obtained in a long-term SCR experiment [13]. In the 0.6 mhigh concrete block (used in the III-1M experiment), the maximum concrete ablation depth was 0.18 m. These results confirm that in the absence of heating, the maximum concrete ablation depth strongly depends on the height of the concrete block.…”
Section: Resultsmentioning
confidence: 52%
See 4 more Smart Citations
“…d 0 , t 0 , and k are fitting parameters defining the maximum concrete ablation depth, the start time, and the time constant, respectively, and d is the concrete ablation depth at the current time t. From the approximation curve in I-8M experiment, d 0 was determined as 0.09 m. This value almost matched the final concrete ablation depth obtained in a long-term SCR experiment [13]. In the 0.6 mhigh concrete block (used in the III-1M experiment), the maximum concrete ablation depth was 0.18 m. These results confirm that in the absence of heating, the maximum concrete ablation depth strongly depends on the height of the concrete block.…”
Section: Resultsmentioning
confidence: 52%
“…However, the concrete ablation depth saturated at 0.1 m in both tests, because the internal heater hindered the Na transfer into the concrete and the reaction area decreased. Previous papers [6,8,13,16] reported a decrease in concrete ablation depth with decreasing reaction area. Na permeated not only the depth of the cylinder, but also the horizontal direction (H ¼ 0 to À0.07 m), because the reaction heat was measured below the internal heater in Fig.…”
Section: Resultsmentioning
confidence: 94%
See 3 more Smart Citations