A Study on the Control Method Without Stratification of Single Duct VAV Terminal Units

Abstract: The objective of this study was to propose a stratification control method for the minimum air flow of a variable air volume (VAV) terminal unit. The minimum air flow rate of the VAV terminal unit is the key factor affecting thermal comfort, indoor air quality (IAQ), stratification and energy consumption depending on the operating mode of the VAV system. Therefore, selecting the proper minimum air flow is very important. In this study, a building simulation was conducted to evaluate the indoor thermal comfort,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 10 publications
0
5
0
Order By: Relevance
“…The typical VAV terminal unit is composed of an air flow sensor, a damper, and a reheating coil [1,10]. In order to control the air flow supplied to each room, the air flow rate is checked through the air flow sensor installed at the inlet of the terminal unit, and the air flow rate is controlled by adjusting the damper opening ratio.…”
Section: Vav Terminal Unit and Volume Dampermentioning
confidence: 99%
See 1 more Smart Citation
“…The typical VAV terminal unit is composed of an air flow sensor, a damper, and a reheating coil [1,10]. In order to control the air flow supplied to each room, the air flow rate is checked through the air flow sensor installed at the inlet of the terminal unit, and the air flow rate is controlled by adjusting the damper opening ratio.…”
Section: Vav Terminal Unit and Volume Dampermentioning
confidence: 99%
“…The data of the fan speed, damper opening ratio, and damper differential pressure were collected through the BAS, and the supply air flow rate was measured using a hot-wire anemometer. Figure 3 and Equation (10) were used to apply the virtual air flow rate measurement procedure and calculate the air flow rate. The uncertainty of the calculated air flow rate was verified using Equations (11) and (12).…”
Section: Verification Of Vav Virtual Air Flow Sensormentioning
confidence: 99%
“…The air flow rate of variable air volume (VAV) terminal unit adjust the supply air flow rate and temperature based on the indoor load, ventilation requirement, and stratification [1][2][3]. Accurate measurement of air flow rate is essential in automatic building control using the VAV system.…”
Section: Introductionmentioning
confidence: 99%
“…Kang et al [11] determined the relationship between supply temperature, air flow rate and energy by height and presented a terminal unit air flow rate control method considering stratification and IAQ. Kim et al [12] presented a method for controlling the supply temperature and air flow rate of a terminal unit to control stratification. Taylor et al [13] conduct an energy study on systems that use the conventional box and dual maximum box control methods.…”
Section: Introductionmentioning
confidence: 99%