A Study on the Hot Spot Temperature in 154kV Power Transformers

Abstract: -The life of a power transformer is dependent on the life of the cellulose paper, which influenced by the hot spot temperature. Thus, the determination of the cellulose paper's life requires identifying the hot spot temperature of the transformer. Currently, however, the power transformer uses a heat run test is used in the factory test to measure top liquid temperature rise and average winding temperature rise, which is specified in its specification. The hot spot temperature is calculated by the winding resi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 26 publications
(8 citation statements)
references
References 4 publications
0
8
0
Order By: Relevance
“…where k h and k e are constants of the core material and n is also material dependent (in the range from 1.5 to 2.5). To separate the no-load loss into eddy-current loss and hysteresis loss, B m in (14) is kept constant by maintaining the ratio (V/f) unchanged in (15). Apply this constraint for the ratio of r, then:…”
Section: Transformer Total Loss Under Harmonic Conditionmentioning
confidence: 99%
See 1 more Smart Citation
“…where k h and k e are constants of the core material and n is also material dependent (in the range from 1.5 to 2.5). To separate the no-load loss into eddy-current loss and hysteresis loss, B m in (14) is kept constant by maintaining the ratio (V/f) unchanged in (15). Apply this constraint for the ratio of r, then:…”
Section: Transformer Total Loss Under Harmonic Conditionmentioning
confidence: 99%
“…In addition, it is difficult to predict and locate the hottest spot in the transformer. One solution is to measure temperature rise in transformers windings with distributed optical fibre sensors embedded along the windings [13,14]. However, it is costly and so its application is limited to large rating station transformers.…”
Section: Introductionmentioning
confidence: 99%
“…al. [7] have estimated the hot spot temperature in the power transformer by the optical fiber sensors and validated it by the conventional heat run test. Gouda et.…”
Section: State Of Artmentioning
confidence: 99%
“…In the past few years, some monitoring methods, including windings displacement [2] and hot spot temperature [3], were applied to detect faults of oil-immersed power transformers, however DGA is still a more convenient and effective online monitoring method comparing to the above methods [4]. If an oil-immersed transformer is subjected to electrical or thermal stress, some gases, emitting from its oil-paper insulation system, mainly including H 2 , CH 4 , C 2 H 6 , C 2 H 4 and C 2 H 2 , can be regarded as a symbol of a potential fault [5].…”
Section: Introductionmentioning
confidence: 99%