International Symposium on Power Electronics Power Electronics, Electrical Drives, Automation and Motion 2012
DOI: 10.1109/speedam.2012.6264413
|View full text |Cite
|
Sign up to set email alerts
|

A study on the transient operation of a salient pole synchronous generator during an inter-turn stator fault with different number of short-circuited turns using F.E.M.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…The comparison of the simulated flux density function of time with the experimental data measured at site as shown in Figure 5 confirmed that the simulation results are in good agreement with the test data. Based on the obtained electromagnetic field solution at rated voltage no-load, the magnetic core losses of the generator are then computed based on the dynamic core loss mode in the time domain and given in (4). Fig.…”
Section: A No-load Simulationmentioning
confidence: 99%
See 1 more Smart Citation
“…The comparison of the simulated flux density function of time with the experimental data measured at site as shown in Figure 5 confirmed that the simulation results are in good agreement with the test data. Based on the obtained electromagnetic field solution at rated voltage no-load, the magnetic core losses of the generator are then computed based on the dynamic core loss mode in the time domain and given in (4). Fig.…”
Section: A No-load Simulationmentioning
confidence: 99%
“…Usually short-circuit simulations are done with the objective of analyzing the stator and damper bar currents behaviour, as in [4]. In this specific paper, the transient operation of a salient pole synchronous generator during an inter-turn stator fault with different number of shortcircuited turns using FEM was investigated.…”
Section: Introductionmentioning
confidence: 99%
“…The formulas of the magneto motive force (MMF) and MFD are analyzed under normal condition and fault. The rules are revealed that FWISC mainly affects MMF but has a very little impact on the permeance per unit area (PPUA) [4] . In addition, the harmonic components of the parallel branch circuit on stator windings and air gap differential coil induction potential are analyzed [5] .…”
Section: Introductionmentioning
confidence: 99%