Abstract:Biocompatibility for the alloys which are used in the human body such as biomaterials depending on corrosion behavior. This study aim at research was to study the corrosion action and the biocompatibility of the samples of SS316L alloy uncoated and coated and compare the effect of coatings on corrosion behavior. Partially Stabilized Zirconia (PSZ) coating was do it by (EPD) technique on SS316L alloy . Structural investigation by using techniques including XRD , microstructure and crystalline of the coatings in… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.