2020
DOI: 10.1016/j.arabjc.2020.01.007
|View full text |Cite
|
Sign up to set email alerts
|

A systematic strategy for rapid identification of chlorogenic acids derivatives in Duhaldea nervosa using UHPLC-Q-Exactive Orbitrap mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
36
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

5
3

Authors

Journals

citations
Cited by 30 publications
(36 citation statements)
references
References 22 publications
0
36
0
Order By: Relevance
“…Peaks 15 and 24 showed the same pseudo-molecular ion [M-H] À at m/z 353.08936 (4.40 ppm, C 16 H 17 O 9 ), and 515.11938 (À0.23 ppm, C 25 H 23 O 12 ), respectively as peaks 2, 9, 12, and 21, 22, 28. By comparing the fragment ion at m/z 191.0547 and the retention time as reported in another study (Liu et al 2018;Cai et al 2020), peaks 15 and 24 were preliminarily inferred as Cis-5-CQA and 1,5-DiCQA, respectively.…”
Section: Analytical Strategymentioning
confidence: 80%
See 2 more Smart Citations
“…Peaks 15 and 24 showed the same pseudo-molecular ion [M-H] À at m/z 353.08936 (4.40 ppm, C 16 H 17 O 9 ), and 515.11938 (À0.23 ppm, C 25 H 23 O 12 ), respectively as peaks 2, 9, 12, and 21, 22, 28. By comparing the fragment ion at m/z 191.0547 and the retention time as reported in another study (Liu et al 2018;Cai et al 2020), peaks 15 and 24 were preliminarily inferred as Cis-5-CQA and 1,5-DiCQA, respectively.…”
Section: Analytical Strategymentioning
confidence: 80%
“… 2018 ; Cai et al. 2020 ), peaks 15 and 24 were preliminarily inferred as Cis-5-CQA and 1,5-DiCQA, respectively.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…All high-resolution MS data were acquired and processed using the Xcalibur version (2.0 software, Thermo Fisher Scientific, San Jose, CA, USA). The compounds were detected by the Compound Discover version 3 using the metabolism workflow templates by the expected compounds predicted method [ 18 ]. The detailed parameters of the workflow template were set as follows: the minimum peak intensity was set as 10000; the maximum element counts were C30 H60 O20; the mass tolerance of MS and MS 2 was within 5 and 10 ppm, respectively; baicalein and phloretin were set as the carbon skeleton; reduction, oxidation was set as Phase I transformation; glucoside conjugation, glucuronide conjugation, pentoside conjugation, methylation was set as Phase II transformation.…”
Section: Methodsmentioning
confidence: 99%
“…us, the metabolites were not completely investigated due to the limitations of the analytical method. In recent years, parallel reaction monitoring (PRM) scanning mode has been developed for achieving the designed ion's MS 2 data [18][19][20].…”
Section: Introductionmentioning
confidence: 99%