1991
DOI: 10.1109/20.278824
|View full text |Cite
|
Sign up to set email alerts
|

A technique for measuring nonlinear bit shift

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

1998
1998
2008
2008

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 70 publications
(14 citation statements)
references
References 7 publications
0
14
0
Order By: Relevance
“…4. Fifth harmonic elimination method was used for this test [5]. At frequencies where both the magnetic and electrical performances are pushed to the limit, nonlinear distortions in the write current waveform or the magnetic field waveform may occur.…”
Section: Resultsmentioning
confidence: 99%
“…4. Fifth harmonic elimination method was used for this test [5]. At frequencies where both the magnetic and electrical performances are pushed to the limit, nonlinear distortions in the write current waveform or the magnetic field waveform may occur.…”
Section: Resultsmentioning
confidence: 99%
“…Fig. 3 shows the amount of NLTS measured by using the fifth harmonic method [5] for each bit length in the experiments using a spinstand system. As can be seen from the figure, when the intervals to the previous transition are T b , 2T b , 3T b and 4T b or longer, the amounts of shifts are 3.1%, 13.3%, 13.9% and 14.2% of a bit interval T b , respectively.…”
Section: R/w Channelmentioning
confidence: 99%
“…6 indicates dependence of the nonlinear transition shift (NLTS) on the DC-bias current for the head-B and the medium-B with DC-erased state. The NLTS was measured using a fifthharmonic cancellation method [5]. The small NLTS value of 5% could be obtained only by the DC-bias current control.…”
Section: Article In Pressmentioning
confidence: 99%
“…The direction of the transition shift in the former case does not vary with a polarity of the previously recorded bit. Therefore, a general pre-compensation method [5] to control the transition position by a write current phase shift can be used. On the other hand, in the later case, the transition shift should change in its direction according to the polarity of the DCerased magnetization.…”
Section: Introductionmentioning
confidence: 99%