An experimental study of the -values and Fano factors for Ar-Xe gaseous mixtures at atmospheric pressures for 5.895 keV X-rays was carried out with two experimental set-ups based on gas proportional scintillation counter techniques. For the 100% Xe, Ar-40% Xe, Ar-20% Xe and Ar-10% Xe mixtures at 800 Torr the measured -values were 21.61 eV, 21.63 eV, 21.64 eV and 21.42 eV, respectively, within an accuracy of 0.21 eV. For the same mixtures the Fano factors were 0.254, 0.258, 0.250 and 0.256, respectively, within an accuracy of about 0.004. For lower Xe concentrations of 5%, 3% and 1% the Fano factors were 0.24, 0.23 and 0.22, respectively. These experimental results are compared with those available in the literature.