2020
DOI: 10.3205/oc000146
|View full text |Cite
|
Sign up to set email alerts
|

A technique for the management of posttraumatic aniridia and aphakia

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2021
2021
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 6 publications
0
2
0
1
Order By: Relevance
“…sutured transsclerally (CV-8 Gore-Tex, cow hitch knot at haptic eyelets, 4-point fixation) 6 n = 1 2020 Riedl JC et al 35 HumanOptics Customflex Artificialiris (n/a) Various techniques inter alia: Sutureless: enclavation of iris fixated IOL (“Sandwich-Implantat”) Sutured? (“Hybridimplantation”) Various techniques inter alia: Sulcus ciliaris, sutureless behind residual iris Sulcus ciliaris, sutured transsclerally (10-0 polypropylene) 41 n = 51 2020 Sousa Silva R et al 10 HumanOptics Customflex Artificialiris (with fiber) Sutured: through IOL eyelets (10-0 polypropylene) Sulcus ciliaris, sutured transsclerally (7-0 CV-8 Gore-Tex) 6 n = 4 2020 Wang et al 7 Ophtec Model 311 Iris Reconstruction Lens Combined implant by manufacturer Various techniques inter alia: Sulcus ciliaris, sutureless Sulcus ciliaris sutured transsclerally (9-0 polypropylene, scleral flaps as needed) 60 n = 38 2020 Wolf A et al 12 HumanOptics Customflex Artificialiris (n/a) Sutured: pierced through IOL plate haptic edges (4-point fixation) Sulcus ciliaris, sutured transsclerally (Hoffman scleral pockets) 1–6 n = 2 2019 Yoeruek E et al 25 HumanOptics Customflex Artificialiris (n/a) Sutureless: 3-piece IOL haptics directly through 0.9mm stab incisions (“belt-loop”) Sulcus ciliaris (? ), sutured transsclerally (10-0 polypropylene, Z-suture, 3-point fixation) 25 n = 5 2017 Mayer C et al 16 HumanOptics Customfle...…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…sutured transsclerally (CV-8 Gore-Tex, cow hitch knot at haptic eyelets, 4-point fixation) 6 n = 1 2020 Riedl JC et al 35 HumanOptics Customflex Artificialiris (n/a) Various techniques inter alia: Sutureless: enclavation of iris fixated IOL (“Sandwich-Implantat”) Sutured? (“Hybridimplantation”) Various techniques inter alia: Sulcus ciliaris, sutureless behind residual iris Sulcus ciliaris, sutured transsclerally (10-0 polypropylene) 41 n = 51 2020 Sousa Silva R et al 10 HumanOptics Customflex Artificialiris (with fiber) Sutured: through IOL eyelets (10-0 polypropylene) Sulcus ciliaris, sutured transsclerally (7-0 CV-8 Gore-Tex) 6 n = 4 2020 Wang et al 7 Ophtec Model 311 Iris Reconstruction Lens Combined implant by manufacturer Various techniques inter alia: Sulcus ciliaris, sutureless Sulcus ciliaris sutured transsclerally (9-0 polypropylene, scleral flaps as needed) 60 n = 38 2020 Wolf A et al 12 HumanOptics Customflex Artificialiris (n/a) Sutured: pierced through IOL plate haptic edges (4-point fixation) Sulcus ciliaris, sutured transsclerally (Hoffman scleral pockets) 1–6 n = 2 2019 Yoeruek E et al 25 HumanOptics Customflex Artificialiris (n/a) Sutureless: 3-piece IOL haptics directly through 0.9mm stab incisions (“belt-loop”) Sulcus ciliaris (? ), sutured transsclerally (10-0 polypropylene, Z-suture, 3-point fixation) 25 n = 5 2017 Mayer C et al 16 HumanOptics Customfle...…”
Section: Discussionmentioning
confidence: 99%
“…The company was acquired by HumanOptics (HumanOptics AG, Erlangen, Germany). 10 HumanOptics obtained Conformité Européenne (CE, since 2011 11 ) and FDA (since 2018 11 ) approval for the Customflex Artificialiris (hereafter referred to as AI) which allows a fully customized colored anterior surface. The HumanOptics AI can be implanted in parts or as a full iris replacement.…”
Section: Introductionmentioning
confidence: 99%
“…Bisher wurden verschiedene Implantationstechniken – z. T. in leichten Variationen – in Abhängigkeit von der Ausgangsituation beschrieben (Abb. 4 ; [ 3 , 17 , 19 , 31 , 36 ]): Sektorförmig ausgeschnittene künstliche Iris, Seite-an-Seite an der Restiris vernäht (Abb. 4 a–e) Neben der Implantation einer kompletten künstlichen Iris können auch nur deren Teilstücke implantiert werden.…”
Section: Chirurgische Herangehensweiseunclassified