2011
DOI: 10.5194/amt-4-1637-2011
|View full text |Cite
|
Sign up to set email alerts
|

A thermal infrared instrument onboard a geostationary platform for CO and O<sub>3</sub> measurements in the lowermost troposphere: Observing System Simulation Experiments (OSSE)

Abstract: Abstract. This paper presents observing system simulation experiments (OSSEs) to compare the relative capabilities of two geostationary thermal infrared (TIR) instruments to measure ozone (O 3 ) and carbon monoxide (CO) for monitoring air quality (AQ) over Europe. The primary motivation of this study is to use OSSEs to assess how these infrared instruments can constrain different errors affecting AQ hindcasts and forecasts (emissions, meteorology, initial condition and the 3 parameters together). The first ins… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
43
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 42 publications
(43 citation statements)
references
References 59 publications
0
43
0
Order By: Relevance
“…Tech., 7, 2185-2201, 2014 www.atmos-meas-tech.net/7/2185/2014/ the simulated observations and the reference state, and the standard deviation of the simulated observations compared to the reference state. The z test has been used in OSSEs before to test the significance of differences between data sets (see Claeyman et al, 2011a;Lahoz et al, 2005). In order to highlight the differences between the results of the statistical tests comparing GEO TIR and GEO TIR+VIS, we calculate the z test for the 0-1 km ozone column only during daytime (07:00-17:00 UTC) (figure not shown).…”
Section: Ozone Retrievals Over a Week Periodmentioning
confidence: 99%
“…Tech., 7, 2185-2201, 2014 www.atmos-meas-tech.net/7/2185/2014/ the simulated observations and the reference state, and the standard deviation of the simulated observations compared to the reference state. The z test has been used in OSSEs before to test the significance of differences between data sets (see Claeyman et al, 2011a;Lahoz et al, 2005). In order to highlight the differences between the results of the statistical tests comparing GEO TIR and GEO TIR+VIS, we calculate the z test for the 0-1 km ozone column only during daytime (07:00-17:00 UTC) (figure not shown).…”
Section: Ozone Retrievals Over a Week Periodmentioning
confidence: 99%
“…In practical implementations of chemical OSSEs, approximated PO simulators are often used, see e.g. Claeyman et al (2011a);Zoogman et al (2011). The idea is to avoid the full RT calculations by a predefinition of typical averaging kernels (AKs) aimed at describing the vertical sensitivity of the observing system.…”
Section: Called These Sensitivity Analyses Chemical Ossesmentioning
confidence: 99%
“…We compared our full RT pseudo-observations with two approximations: one based on the use of a single average scene-independent A over the whole region of study (hereafter referred to as approximation 1), and the other based on the use of a limited scene-dependent set of A ( T ), as a function of the thermal contrast ( T ) between the surface and the lowest air layer (hereafter referred to as approximation 2). Approximation 1 and 2 are inspired from the approximations recently used to carry out fast OSSEs aimed at studying the impact on LT ozone monitoring of GEO-CAPE (GEOstationary Coastal and Air Pollution Events) (Zoogman et al, 2011) and MAGEAQ (Claeyman et al, 2011a), respectively. The approximation 1 A was obtained by running our pseudo-observations simulator only once over a hypothetical scene with standard summer mid-latitudes climatological vertical profiles of temperature, pressure and trace gases, and a standard surface temperature.…”
Section: Approximated Averaging Kernelsmentioning
confidence: 99%
See 2 more Smart Citations