2004
DOI: 10.1016/j.fuel.2003.11.012
|View full text |Cite
|
Sign up to set email alerts
|

A thermoanalytical study of the co-pyrolysis of coal-tar pitch and petroleum pitch

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
42
0
1

Year Published

2005
2005
2023
2023

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 86 publications
(43 citation statements)
references
References 9 publications
0
42
0
1
Order By: Relevance
“…The first peak appears at 245 °C, and the weight loss is 8 wt%. The first peak can be attributed to the distillation of the volatile compounds that are stable at their boiling point [13], while the second peak at 345 °C indicates the removal of light compounds and gases due to cracking and polymerization reactions. In addition, it was observed that during distillation the temperature increased dramatically from room temperature to 200 °C (7 °C/min) and then it slowed down at 245 °C (1.83 °C/min) and 345 °C (1.22 °C/min).…”
Section: Resultsmentioning
confidence: 99%
“…The first peak appears at 245 °C, and the weight loss is 8 wt%. The first peak can be attributed to the distillation of the volatile compounds that are stable at their boiling point [13], while the second peak at 345 °C indicates the removal of light compounds and gases due to cracking and polymerization reactions. In addition, it was observed that during distillation the temperature increased dramatically from room temperature to 200 °C (7 °C/min) and then it slowed down at 245 °C (1.83 °C/min) and 345 °C (1.22 °C/min).…”
Section: Resultsmentioning
confidence: 99%
“…Distillation of coal tar leaves behind coal tar pitch (CTP), a thick black liquid with viscosity even higher than coal tar. CTP is a complex mixture of polyaromatic hydrocarbons [1,2]. Problems of separation into components are somewhat similar as in petroleum [3].…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, halogen determination in this matrix is still more difficult when considering the risks of losses and contamination during the sample preparation step. [2][3][4]10,14 Despite the fact that the determination of major elements, such as sulfur, in pitch can be carried out using elemental analyzers, 5,13,15,16 these instruments are not suitable for determination of other non-metals (e.g., Br and I). Moreover, there are no methods in the literature for pitch digestion for further simultaneous determination of halogens and sulfur.…”
Section: Introductionmentioning
confidence: 99%