1995
DOI: 10.1016/s0099-2399(06)80971-4
|View full text |Cite
|
Sign up to set email alerts
|

A three-dimensional finite-element stress analysis of an endodontically prepared maxillary central incisor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
53
0
2

Year Published

2010
2010
2024
2024

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 55 publications
(57 citation statements)
references
References 21 publications
2
53
0
2
Order By: Relevance
“…Hence, to predict VRF it is only necessary to evaluate the state of stresses prior to fracture. Such studies were conducted for various root configurations and lateral condensation conditions using 3D Finite Element analyses (FEA) (Ricks-Williamson et al, 1995;Yaman et al, 1995;Telli et al, 1999). Latter works employing this concept studied the effect of the canal's cross-section shape and size, external root boundary and remaining dentin thickness (Lertchirakarn et al, 1999(Lertchirakarn et al, , 2003Sathorn et al, 2005a).…”
Section: Introductionmentioning
confidence: 99%
“…Hence, to predict VRF it is only necessary to evaluate the state of stresses prior to fracture. Such studies were conducted for various root configurations and lateral condensation conditions using 3D Finite Element analyses (FEA) (Ricks-Williamson et al, 1995;Yaman et al, 1995;Telli et al, 1999). Latter works employing this concept studied the effect of the canal's cross-section shape and size, external root boundary and remaining dentin thickness (Lertchirakarn et al, 1999(Lertchirakarn et al, , 2003Sathorn et al, 2005a).…”
Section: Introductionmentioning
confidence: 99%
“…Previous studies have shown that the mean maximum spreader load applied during lateral compaction ranges from 1 to 3 kg [12,30]. We applied a standardized load of 1.5 kg to the spreaders during root canals obturation, which was in accordance with the study of Holcomb et al [23] where they suggested that 1.5 kg load to be regarded as a limit in clinical practice.…”
Section: Discussionmentioning
confidence: 69%
“…Von Mises's equivalent stress criterion (s vM ) was chosen because it represents the general combination of absolute values according to all the stress produced and acting as an excellent parameter for descriptive analysis of the obtained data (Ricks-Williamson et al 1995;Zarone et al 2006). The maximum s vM value was obtained, as well as for specific areas in each model (Figures 3 and 4).…”
Section: Computer Methods In Biomechanics and Biomedical Engineering 517mentioning