A Three Dimensional Virtual System Used to Analyze the Normal and Prosthetic Joint of the Hip

Abstract: Treatment of hip pathology has evolved over the last two centuries, ranging from rudimentary surgical procedures to modern hip arthroplasty, with an explosion marked in the last 30 years, considered to be one of the most successful surgeries to date. Hip arthroplasty is a permanent challenge due to the desire to discover the "supreme prosthesis", for which competition is still open. Hip disorders requiring prosthesis show a change in articular morphology. Among the most common medical conditions that have as f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(4 citation statements)
references
References 8 publications
0
4
0
Order By: Relevance
“…The following simplifying assumptions were used in the analyses of the three orthopaedic systems: Knowing that orthopaedic cement, used in these orthopaedic prostheses, provides stability and fixation of the components, it was not geometrically modelled, and its behaviour was replaced with the use of bonded elements that practically provide cohesion of the elements between themselves [ 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 ]; It is known that, during the human gait, the variation of the force occurring in the hip joint varies between values of 0 N and about 2300 N. We have considered that it is sufficient to use an equivalent force that has a linear variation between the values of 800 N (characteristic of the orthostatic position) and 2300 N (maximum value of the force during normal human gait [ 26 , 27 , 28 , 29 , 30 , 31 , 39 , 42 ]); For revision prostheses using a morcellated bone graft, the study was considered to be performed after complete osseointegration of the graft, when it acquires the appearance and properties of the trabecular bone [ 26 , 27 , 28 , 39 ]. …”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The following simplifying assumptions were used in the analyses of the three orthopaedic systems: Knowing that orthopaedic cement, used in these orthopaedic prostheses, provides stability and fixation of the components, it was not geometrically modelled, and its behaviour was replaced with the use of bonded elements that practically provide cohesion of the elements between themselves [ 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 ]; It is known that, during the human gait, the variation of the force occurring in the hip joint varies between values of 0 N and about 2300 N. We have considered that it is sufficient to use an equivalent force that has a linear variation between the values of 800 N (characteristic of the orthostatic position) and 2300 N (maximum value of the force during normal human gait [ 26 , 27 , 28 , 29 , 30 , 31 , 39 , 42 ]); For revision prostheses using a morcellated bone graft, the study was considered to be performed after complete osseointegration of the graft, when it acquires the appearance and properties of the trabecular bone [ 26 , 27 , 28 , 39 ]. …”
Section: Methodsmentioning
confidence: 99%
“…Knowing that orthopaedic cement, used in these orthopaedic prostheses, provides stability and fixation of the components, it was not geometrically modelled, and its behaviour was replaced with the use of bonded elements that practically provide cohesion of the elements between themselves [ 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 ];…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations