1996
DOI: 10.1080/09398368.1996.11463396
|View full text |Cite
|
Sign up to set email alerts
|

A Three-Phase Four-Wire Shunt Active Filter Employing a Conventional Three-Leg Converter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0
1

Year Published

1998
1998
2017
2017

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 0 publications
0
6
0
1
Order By: Relevance
“…Die in Bild 6 dokumentierten Meggr6flenverl~iufe wurden im Inselnetzbetrieb ermittelt. [7,8]). Ausgehend yon einer Leerlaufeinstellung werden die Netzinnenwidersdinde am PCC durch parametrische online Identifikationsverfahren gesch~itzt und die Regler parametriert.…”
Section: Priifstandsergebnisse Fiir Den Inselbetriebunclassified
“…Die in Bild 6 dokumentierten Meggr6flenverl~iufe wurden im Inselnetzbetrieb ermittelt. [7,8]). Ausgehend yon einer Leerlaufeinstellung werden die Netzinnenwidersdinde am PCC durch parametrische online Identifikationsverfahren gesch~itzt und die Regler parametriert.…”
Section: Priifstandsergebnisse Fiir Den Inselbetriebunclassified
“…There are many structures to solve these problems [7] such as the three H-bridge topology, the three-leg split-capacitor topology and four-leg topology. In this paper, the three-leg split-capacitor topology with six IGBTs is used because this topology provides a good performance for a harmonic elimination [8] and it uses the lower number of power semiconductor devices [9].…”
Section: Introductionmentioning
confidence: 99%
“…The fourth part is the DC bus voltage control of APF. The one problem of the three-leg split-capacitor topology is the voltage deviation between the dc capacitors (C dc,1 , C dc,2 ) [9]. For this reason, the design of voltage loop controllers and control strategy are used to keep the balanced voltage across the capacitors (V dc,1 ,V dc,2 ).…”
Section: Introductionmentioning
confidence: 99%
“…Up to now, in many industrial applications, there is a great interest in four-leg inverters for three-phase four-wire applications. Such as power generation, distributed energy systems [1][2][3][4], active power filtering [5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20], uninterruptible power supplies, special control motors configurations [21][22][23][24][25], military utilities, medical equipment [26][27] and rural electrification based on renewable energy sources [28][29][30][31][32]. This kind of inverter has a special topology because of the existence of the fourth leg; therefore it needs special control algorithm to fulfil the subject of the neutral current circulation which was designed for.…”
Section: Introductionmentioning
confidence: 99%