2017
DOI: 10.1109/tpel.2016.2639063
|View full text |Cite
|
Sign up to set email alerts
|

A Three-Vector Modulation Strategy for Indirect Matrix Converter Fed Open-End Load to Reduce Common-Mode Voltage With Improved Output Performance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0
3

Year Published

2018
2018
2022
2022

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 23 publications
(14 citation statements)
references
References 36 publications
0
11
0
3
Order By: Relevance
“…To reduce the CMV of the IMC, non-zero vector approaches are introduced to control the inverter stage, i.e. only active vectors are used to generate the desired output voltage [12], [13], [16], [18]. Among non-zero vector approaches, the near state PWM technique is preferred to others due to its advantages, such as smaller total harmonic distortion (THD) of the line-to-line output voltage and low switching losses [11].…”
Section: B Proposed Svm For Inverter Stage To Reduce CMVmentioning
confidence: 99%
See 2 more Smart Citations
“…To reduce the CMV of the IMC, non-zero vector approaches are introduced to control the inverter stage, i.e. only active vectors are used to generate the desired output voltage [12], [13], [16], [18]. Among non-zero vector approaches, the near state PWM technique is preferred to others due to its advantages, such as smaller total harmonic distortion (THD) of the line-to-line output voltage and low switching losses [11].…”
Section: B Proposed Svm For Inverter Stage To Reduce CMVmentioning
confidence: 99%
“…From (18) and 20, it should be noted that the duty ratios of the rectifier and inverter stages must be non-negative and lower than or equal to unity. From (24), the proposed strategy is suitable to drive the IMC operating at a high VTR range.…”
Section: Voltage Transfer Ratiomentioning
confidence: 99%
See 1 more Smart Citation
“…The amplitude of 2f c is the highest among all the harmonic components, up to 0.93 under the condition of m = 0.5, followed by the component of f c ± 6f in with the amplitude of 0.53. According to literature [18][19][20], high-frequency common-mode voltages are the main cause of bearing damage, winding fault, electromagnetic interference. The above analysis can accurately describe the amplitude of these common mode voltages, thus providing reference for the suppression of common mode voltage.…”
Section: Frequency(khz)mentioning
confidence: 99%
“…In such a configuration, it is essential to eliminate the CMV that is inevitably created by usual PWM control strategies [19], [20]. Some literature reported on these issues of circulating currents and CMV cancellation in the OEW fed by dual inverters [18]- [21], and by DMCs [22], [23]. However, the main focus of this paper is not the CMV and circulating currents, but to get the optimum condition for sharing the power of both MCs by controlling the reference voltage space vectors and analyze the system.…”
Section: Introductionmentioning
confidence: 99%