2021
DOI: 10.1016/j.snb.2020.128842
|View full text |Cite
|
Sign up to set email alerts
|

A versatile signal-on electrochemical biosensor for Staphylococcus aureus based on triple-helix molecular switch

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
46
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 74 publications
(46 citation statements)
references
References 45 publications
0
46
0
Order By: Relevance
“…In the work performed by Cai and co-workers [ 40 ], the amplification step was performed for 45 min, which is a shorter time compared with the original 2-h SDA process which has been considered too long for the development of biosensors. Moreover, SDA reactions have shown high sensitivity to background DNA, which will coamplify following non-specific primer binding as a result of reduced stringency conditions present at 37 °C.…”
Section: Isothermal Dna Amplification-based Biosensors: State Of Tmentioning
confidence: 99%
See 3 more Smart Citations
“…In the work performed by Cai and co-workers [ 40 ], the amplification step was performed for 45 min, which is a shorter time compared with the original 2-h SDA process which has been considered too long for the development of biosensors. Moreover, SDA reactions have shown high sensitivity to background DNA, which will coamplify following non-specific primer binding as a result of reduced stringency conditions present at 37 °C.…”
Section: Isothermal Dna Amplification-based Biosensors: State Of Tmentioning
confidence: 99%
“…Moreover, Arabidopsis and tomato plants were analysed by a multiplexed RPA-based SERS platform [ 33 ] for the detection of P. syringae , B. cinerea and F. oxyspurim. Finally, the SDA-based biosensor was applied to the detection of E. coli in spiked lake water, tap water and honey samples [ 40 ]. Some of the mentioned works showed good recovery values [ 19 , 24 , 40 ] and correlated well with results obtained with other techniques such as qPCR [ 28 , 32 ] or PCR and gel electrophoresis [ 20 , 29 , 33 ].…”
Section: Isothermal Dna Amplification-based Biosensors: Key Factormentioning
confidence: 99%
See 2 more Smart Citations
“…An electrochemical biosensor for Staphylococcus aureus was designed, based on a triple-helix molecular switch, which can control the switching of electrochemical signals [116]. The biosensor showed a dynamic range from 30 to 3 x 10 8 CFUmL -1 , with a detection limit of 8 CFUmL -1 .…”
Section: Pathogenic Bacteriamentioning
confidence: 99%