2020
DOI: 10.1094/mpmi-04-20-0082-ta
|View full text |Cite|
|
Sign up to set email alerts
|

A Viable New Strategy for the Discovery of Peptide Proteolytic Cleavage Products in Plant-Microbe Interactions

Abstract: Small peptides that are proteolytic cleavage products (PCPs) less than 100 amino acids are emerging as key signaling molecules that mediate cell-to-cell communication and biological processes that occur between and within plants, fungi, and bacteria. Yet, the discovery and characterization of these molecules is largely overlooked. Today, selective enrichment and subsequent characterization by mass spectrometry (MS)-based sequencing offers the greatest potential for their comprehensive characterization, however… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 74 publications
0
8
0
Order By: Relevance
“…Peptides were analyzed by liquid chromatography and tandem mass spectrometry (LC-MS/MS) as previously described ( Villalobos Solis et al., 2020 ) using a Proxeon EASY-nLC 1200 liquid chromatography pump (Thermo Fisher Scientific) coupled to a Q Exactive Plus mass spectrometer (Thermo Fischer Scientific). Briefly, peptides were separated on an in-house-pulled nanospray emitter of 75 μm inner diameter packed with 30 cm of Kinetex C18 resin (1.7 μm, 100 Å, Phenomenex).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Peptides were analyzed by liquid chromatography and tandem mass spectrometry (LC-MS/MS) as previously described ( Villalobos Solis et al., 2020 ) using a Proxeon EASY-nLC 1200 liquid chromatography pump (Thermo Fisher Scientific) coupled to a Q Exactive Plus mass spectrometer (Thermo Fischer Scientific). Briefly, peptides were separated on an in-house-pulled nanospray emitter of 75 μm inner diameter packed with 30 cm of Kinetex C18 resin (1.7 μm, 100 Å, Phenomenex).…”
Section: Methodsmentioning
confidence: 99%
“…MS data were acquired with the Thermo Xcalibur software v4.27.19 using the top 10 data-dependent acquisition method. Other spectral data acquisition parameters have been reported before ( Villalobos Solis et al., 2020 ).…”
Section: Methodsmentioning
confidence: 99%
“…This may cause a problem for studying plant SSPs that contain a large portion of IDRs using proteomics approaches because MS has lower sensitivity than transcriptome sequencing. To increase the sensitivity of detecting SSPs in plants, it is necessary to enrich for IDRs containing proteins and low molecular weight proteins in protein extract using gel filters 95 or ultrafiltration devices 96 , 97 .…”
Section: Computational and Experimental Approaches For Discovery Of Ssps In Plantsmentioning
confidence: 99%
“…This classical approach for the discovery of novel natural products starts with an enrichment strategy to selectively isolate molecules of interest from highly complex crude extracts. For SSPs, common cellular extraction techniques use size exclusion ultrafiltration strategies, such as molecular weight cut-off spin column filters, to selectively enrich for low molecular weight protein fractions 96 , 97 . Other techniques include gel-based separations 49 , 95 , 133 , solvent extractions 89 , 134 , and size exclusion chromatography 134 , 135 .…”
Section: Strategies For Elucidating the Function Of Plant Sspsmentioning
confidence: 99%
“…MS data was acquired with the Thermo Xcalibur software v4.27.19 using the topN method where N could be up to 10. Other spectral data acquisition parameters have been reported before [5].…”
Section: Figurementioning
confidence: 99%