2019
DOI: 10.1021/acs.jced.8b00965
|View full text |Cite
|
Sign up to set email alerts
|

A Volumetric and Viscosity Study for the Binary Mixtures of Ammonium-Based Asymmetrical Gemini Ionic Liquids with Alcohols at T = 293.15–333.15 K

Abstract: In this work, the experimental densities and dynamic viscosities of binary mixtures of ammonium-based roomtemperature asymmetrical Gemini ionic liquids (GILs) 1-trimethylammonium-3-(pyridinium) propane bisdicyanamide ([N 111 C 3 Py][DCA] 2 ) and 1-trimethylammonium-3-(1-methylpiperidinium) propane bisdicyanamide ([N 111 C 3 MPi][DCA] 2 ) with methanol (MeOH) or ethanol (EtOH) over the entire concentration range were, respectively, determined experimentally at temperatures of (293.15, 303.15, 313.15, 323.15, an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(5 citation statements)
references
References 42 publications
0
5
0
Order By: Relevance
“…The viscosity values were obtained from the rolling time of a stainless ball in a liquid sample. The values of sample viscosity were directly automatically calculated according to the rolling time . The automatic microviscometer can control the temperature and rolling time with an uncertainty of 0.01 K and 0.001 s, respectively.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The viscosity values were obtained from the rolling time of a stainless ball in a liquid sample. The values of sample viscosity were directly automatically calculated according to the rolling time . The automatic microviscometer can control the temperature and rolling time with an uncertainty of 0.01 K and 0.001 s, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…The values of sample viscosity were directly automatically calculated according to the rolling time. 25 The automatic microviscometer can control the temperature and rolling time with an uncertainty of 0.01 K and 0.001 s, respectively. In addition, the viscometer is calibrated by employing ultrapure water, and the relative expanded uncertainty in this work is 0.02.…”
Section: Introductionmentioning
confidence: 99%
“…With an increase in temperature, the number of the free dipoles of carboxylic acid molecules in the mixture increases due to dissociation of existing bonds and more interaction with available ions of the IL, leading to a decrease in V m E with temperature. 87 Also, the decrease in the V m E with temperature can be attributed to the greater packing efficiency 88 between the mixing components due to the expansion in free volume between the IL ions with temperature.…”
Section: Thermodynamic Propertiesmentioning
confidence: 99%
“…FigureS3: Density of pure ethanol at 101.3 kPa as a function of temperature. Symbols are experimental results from this work and measurement data from the literature[3][4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21] as denoted in the legend. The line denotes the fit of the data of this work as described in the main text.…”
mentioning
confidence: 99%
“…FigureS4: Relative deviation between experimental densities from this work or literature[3][4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21] as denoted in the legend and the fit to this work's data as described in the main text.…”
mentioning
confidence: 99%