2013
DOI: 10.1016/j.talanta.2013.03.054
|View full text |Cite
|
Sign up to set email alerts
|

A vortex-assisted MSPD method for the extraction of pesticide residues from fish liver and crab hepatopancreas with determination by GC–MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
9
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 65 publications
(10 citation statements)
references
References 29 publications
1
9
0
Order By: Relevance
“…RSD values lower than 10% and 16% for intraday and interday precision respectively were obtained (Table 2), which are in the acceptance range of the DG SANCO/12571/2013 of the European Quality Control Guidelines (RSD < 20%). It is worth noting that the obtained recoveries and relative standard deviation are comparable or even better to those provided by other authors for the determination of some of these pollutants by MSPD in fish (Gaunt & Barker, 2000;Souza-Caldas et al, 2013).…”
Section: Methods Validationsupporting
confidence: 82%
See 2 more Smart Citations
“…RSD values lower than 10% and 16% for intraday and interday precision respectively were obtained (Table 2), which are in the acceptance range of the DG SANCO/12571/2013 of the European Quality Control Guidelines (RSD < 20%). It is worth noting that the obtained recoveries and relative standard deviation are comparable or even better to those provided by other authors for the determination of some of these pollutants by MSPD in fish (Gaunt & Barker, 2000;Souza-Caldas et al, 2013).…”
Section: Methods Validationsupporting
confidence: 82%
“…2.5 g of fresh tissue); therefore, approximately 5-fold lower LOQ values are achieved when referred to fresh sample. By comparing the LOQs obtained by the proposed methodology with those reported in the literature using MSPD in fish, better sensitivity is attained (Gaunt & Barker, 2000;Souza-Caldas et al, 2013).…”
Section: Methods Validationmentioning
confidence: 92%
See 1 more Smart Citation
“…Briefly, after dispersion of the sample in the mortar with the solid support, the resulting homogeneous powder is placed into a centrifuge polypropylene tube with the appropriate elution solvent to obtain a suspension. Then, the tube content is vortexed for 1 min and centrifuged for 10 min to collect the final extract [49]. Compared to traditional MSPD with elution in a vacuum manifold, recoveries of pesticides in fish liver [49] obtained with the vortex-assisted procedure were slightly, but not significantly, lower.…”
Section: Vortex-assisted Mspd (Va-mspd)mentioning
confidence: 96%
“…Then, the tube content is vortexed for 1 min and centrifuged for 10 min to collect the final extract [49]. Compared to traditional MSPD with elution in a vacuum manifold, recoveries of pesticides in fish liver [49] obtained with the vortex-assisted procedure were slightly, but not significantly, lower. However the advantage of faster extraction claimed by the authors was not so evident.…”
Section: Vortex-assisted Mspd (Va-mspd)mentioning
confidence: 96%