2019
DOI: 10.2116/analsci.19p314
|View full text |Cite
|
Sign up to set email alerts
|

A Water-soluble Fluorescent Probe for Rapid Detection of Sulfur Dioxide Derivatives

Abstract: The content of sulfur dioxide derivatives in cells is closely related to life and health. Therefore, it is essential to detect the content of sulfur dioxide derivatives in cells under physiological conditions to ensure life and health. In this paper, a novel sulfur dioxide derivative fluorescent water-soluble probe ((E)-1,1,3-trimethyl-2-(2-(naphthalen-1-yl)vinyl)-1H-3λ 4-benzo[e]indole, TNB) was synthesized by using naphthalene formaldehyde (1) and 1,1,2,3-tetramethyl-1H-3λ 4benzo[e] indole (2) as raw materia… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 35 publications
0
5
0
Order By: Relevance
“…3b). According to the detection limit formula LOD = 3σ/k (Where σ is the standard deviation of the blank sample measurement, k is the slope between fluorescence intensity and O 3 concentration) (Zhao et al 2020), the minimum detection concentration is calculated to be 43 nM, which indicates that the probe can be used to detect trace amounts of O 3 in a physiological environment.…”
Section: Study On Spectral Performance Of Bctmentioning
confidence: 99%
“…3b). According to the detection limit formula LOD = 3σ/k (Where σ is the standard deviation of the blank sample measurement, k is the slope between fluorescence intensity and O 3 concentration) (Zhao et al 2020), the minimum detection concentration is calculated to be 43 nM, which indicates that the probe can be used to detect trace amounts of O 3 in a physiological environment.…”
Section: Study On Spectral Performance Of Bctmentioning
confidence: 99%
“…Although several gas chromatographic methods have been developed, these methods require relatively complicated instruments. [13][14][15] Further, although the fluorescence method has advantages in terms of simplicity, sensitivity and rapidness, 16 TEA does not exhibit intrinsic fluorescence, and it should be difficult to apply fluorescence derivatization because TEA does not have a derivatizable moiety. 17 From these aspects, we attempted to develop a simple and rapid fluorescence microplate assay for TEA based on promoting the dimerization of benzofuran-2-boronic acid.…”
Section: Fluorescence Microplate Assay For Teamentioning
confidence: 99%
“…As hydrophilic liquid materials can be dissolved in or miscible to water media, they are expected to function as sensing materials to highly toxic metals. 17,[39][40]45 Analytical Sciences Figure 4a-c, blue lines indicate that proBz was in air for 1h, and proPy and proPhen were in air for 1 day.…”
Section: Conclusion (Optional)mentioning
confidence: 99%
“…Furthermore, the chemical modification such as a water solubility into these materials can provide the opportunity to use for colorimetric fluorescent probes in various fields. 17,[39][40][41][42][43][44][45] Herein, we report on facile synthesis for a series of SFLs with a low environmental load as well as the characterization of mixtures with SFLs.…”
Section: Introductionmentioning
confidence: 99%