A wearable cardioverter defibrillator with a low false alarm rate

Abstract: Introduction: A wearable cardioverter defibrillator (WCD) is indicated in appropriate patients to reduce the risk for sudden cardiac death. Challenges for patients wearing a WCD have been frequent false shock alarms primarily due to electrocardiogram noise and wear discomfort. The objective of this study was to test a contemporary WCD designed for reduced false shock alarms and improved comfort.Methods: One hundred and thirty patients with left ventricular ejection fraction ≤40% and an active implantable cardi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 23 publications
0
4
0
Order By: Relevance
“…This difference in daily wear hours may have several reasons, among others a fast recovery of symptoms in younger patients, wearing discomfort, inadequate education, lack of high‐risk warning, undiligent follow‐up and being physically more active. Moreover, false alarms due to wear discomfort and electrocardiogram noise might also be reasons 10 . The ‘symptom’ in heart failure might not only be depicted by NYHA class but also should be multifactorial (subjective feeling, blood biomarkers like BNP, Creatinin and objective clinical parameters like EF, 6‐MWT, Spirometry).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…This difference in daily wear hours may have several reasons, among others a fast recovery of symptoms in younger patients, wearing discomfort, inadequate education, lack of high‐risk warning, undiligent follow‐up and being physically more active. Moreover, false alarms due to wear discomfort and electrocardiogram noise might also be reasons 10 . The ‘symptom’ in heart failure might not only be depicted by NYHA class but also should be multifactorial (subjective feeling, blood biomarkers like BNP, Creatinin and objective clinical parameters like EF, 6‐MWT, Spirometry).…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, false alarms due to wear discomfort and electrocardiogram noise might also be reasons. 10 The 'symptom' in heart failure might not only be depicted by NYHA class but also should be multifactorial (subjective feeling, blood biomarkers like BNP, Creatinin and objective clinical parameters like EF, 6-MWT, Spirometry).…”
Section: Predictors Of Compliancementioning
confidence: 99%
“…1 The reasons for patient reluctance to continue with this device revolves around two issues: wear discomfort and frequent false alarms that are not only a nuisance but may interrupt sleep and generate anxiety. The study by Poole et al 2 The function of the proprietary algorithm is well described by the authors in their report. The study enrolled implantable cardioverter-defibrillator (ICD) patients, thereby permitting comparison of WCD diagnostics with retrieved intracardiac electrograms in each individual.…”
mentioning
confidence: 93%
“… 1 The reasons for patient reluctance to continue with this device revolves around two issues: wear discomfort and frequent false alarms that are not only a nuisance but may interrupt sleep and generate anxiety. The study by Poole et al 2 in this issue reports the function of a novel WCD platform that aimed to resolve these persistent problems. The results are impressive.…”
mentioning
confidence: 99%