2012 International Conference on Biomedical Engineering and Biotechnology 2012
DOI: 10.1109/icbeb.2012.46
|View full text |Cite
|
Sign up to set email alerts
|

A Wearable Wireless General Purpose Bio-signal Acquisition Prototype System for Home Healthcare

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 6 publications
0
8
0
Order By: Relevance
“…In this new arrangement, the data readings had always maximum priority in the time-sharing of kernel task management, leaving the rest of the time available for the other purposes such as data processing, saving and transmission. In comparison to other systems previously reported and presented in Table 1 [5,[9][10][11]13], the proposed system consumes more power, due to the implementation of a more expensive communication protocol. Although other platforms consume less energy, they also provide fewer channels, less signal resolution and lower sampling rates, which renders in a data package much smaller than the data package transmitted by the proposed platform.…”
Section: Comparison With State-of-the-art Platformsmentioning
confidence: 87%
See 2 more Smart Citations
“…In this new arrangement, the data readings had always maximum priority in the time-sharing of kernel task management, leaving the rest of the time available for the other purposes such as data processing, saving and transmission. In comparison to other systems previously reported and presented in Table 1 [5,[9][10][11]13], the proposed system consumes more power, due to the implementation of a more expensive communication protocol. Although other platforms consume less energy, they also provide fewer channels, less signal resolution and lower sampling rates, which renders in a data package much smaller than the data package transmitted by the proposed platform.…”
Section: Comparison With State-of-the-art Platformsmentioning
confidence: 87%
“…Other studies have been applying different wireless communication protocols (Table 1) [5,[9][10][11][12][13]. These systems provide 16 channels or less, typically less than 24 bits resolution per channel and sampling frequencies of less than 1000 SPS.…”
Section: Comparison With State-of-the-art Platformsmentioning
confidence: 99%
See 1 more Smart Citation
“…Each EMG channel is filtered through a sixth order bandpass filter (1)(2)(3)(4)(5) with one pole at low frequency (3Hz) to remove the motion artifacts and five poles to achieve a Butterworth filter at 500Hz.…”
Section: A the Filtering Subsystemmentioning
confidence: 99%
“…To date biometric devices can be grouped into of three classes: High performance/quality EEG/EMG/ECG devices which are instrumented as laboratory tools [1], [2] or as small distance portable systems [3], [4], [5]; Wearable motion capture systems [6] provided with different flavours of sensing and wireless options [7], [8]; and low cost combined motion and EMG sensors which recently appeared on the market (Liveathos TM , and Myo TM ). Laboratory tools are very accurate and can be scaled to complex situations, but their settling prevent the portability of the system.…”
Section: Introductionmentioning
confidence: 99%