2018
DOI: 10.1109/tpwrd.2017.2704108
|View full text |Cite
|
Sign up to set email alerts
|

A Wide-Range Model for Metal-Oxide Surge Arrester

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
16
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 56 publications
(21 citation statements)
references
References 21 publications
2
16
0
Order By: Relevance
“…MWR(MOSA Wide-range) model(2017) proposed by Valdemir S. Brito was developed and validated based on MOSA electrical behavior in each one of the three operating regions of the zinc-oxide (ZnO) surge arresters, and in a database composed of voltage and current waveforms measured from tests performed in twelve ZnO varistors having different physical dimensions and electrical characteristicfrom five different manufacturers. It was shown that most of the waveform simulation results (under 8/20μs, 4/10μs and 3/6μs) were similar with the experimental data but the error was larger for the current impulse 1.5/26μs [14] . Some models were analyzed and studied by He Yuwei [15] and suggestion was put forward for reference.…”
Section: Introductionsupporting
confidence: 53%
See 4 more Smart Citations
“…MWR(MOSA Wide-range) model(2017) proposed by Valdemir S. Brito was developed and validated based on MOSA electrical behavior in each one of the three operating regions of the zinc-oxide (ZnO) surge arresters, and in a database composed of voltage and current waveforms measured from tests performed in twelve ZnO varistors having different physical dimensions and electrical characteristicfrom five different manufacturers. It was shown that most of the waveform simulation results (under 8/20μs, 4/10μs and 3/6μs) were similar with the experimental data but the error was larger for the current impulse 1.5/26μs [14] . Some models were analyzed and studied by He Yuwei [15] and suggestion was put forward for reference.…”
Section: Introductionsupporting
confidence: 53%
“…Comply with GB 11032-2010 "Metal-oxide surge arresters without gaps for A.C. systems" during the test [17] , and MOVs (Table 1) were subjected to impulse currents with the following wave shapes: 8/20μs, 30/80μs and steep current with front time about 1μs. The residual voltage and energy absorption of MOVs under the corresponding impulse current were measured and recorded in Table III. The residual voltage values can be obtained easily, while energy absorption values in the test (Em) and simulation (Es) could be calculated using (14).…”
Section: B Test Methods and Resultsmentioning
confidence: 99%
See 3 more Smart Citations