2014
DOI: 10.1016/j.bios.2013.08.026
|View full text |Cite
|
Sign up to set email alerts
|

A wireless and sensitive detection of octachlorostyrene using modified AuNPs as signal-amplifying tags

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 28 publications
0
6
0
Order By: Relevance
“…Besides, the ME biosensor method is comparatively fast, requiring only several minutes whereas TaqMan-based quantitative real-time PCR (qPCR) requires 2–3 h, and its operation principle is relatively easy 40 . Furthermore, previous researches 19 , 27 , 40 have also demonstrated the significant advantages in terms of sensitivity, cost and ease of use of the ME biosensor methodology. For the detection of CSFV E2 antibody, various published methods are summarized in Table 1 , showing the superior performance of our biosensor.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Besides, the ME biosensor method is comparatively fast, requiring only several minutes whereas TaqMan-based quantitative real-time PCR (qPCR) requires 2–3 h, and its operation principle is relatively easy 40 . Furthermore, previous researches 19 , 27 , 40 have also demonstrated the significant advantages in terms of sensitivity, cost and ease of use of the ME biosensor methodology. For the detection of CSFV E2 antibody, various published methods are summarized in Table 1 , showing the superior performance of our biosensor.…”
Section: Resultsmentioning
confidence: 99%
“… From equation ( 2 ), we can conclude that an extra mass load on the sensor surface leads to a decrease of f 0 . As the resonance frequency is sensitive to the mass change, the sensor modified with a chemically or biologically sensitive polymer can be designed for detection of several bacteria and protein, such as Bacillus anthracis spores 24 , 25 , Salmonella typhimurium 26 , octachlorostyrene 27 . As well known, signal amplification is a critical challenge to the biological detection.…”
Section: Introductionmentioning
confidence: 99%
“…The resonance frequency of WMS was measured by a magnetoelastic sensor reader which was interfaced to a computer via a RS232 port for data display and storage [12][13][14][15] (Fig. S1, see Supplementary data), and measurement resolution is approximately 0.5 Hz.…”
Section: Apparatusmentioning
confidence: 99%
“…S1 (see Supplementary data). The sensor platform is made of a magnetoelastic material of amorphous ferromagnetic alloys [12][13][14][15], which possesses the property of elongating or contracting along the direction of an applied external magnetic field. In the presence of a time-varying magnetic field, the sensor resonator undergoes a corresponding change of oscillating shape, giving rise to a mechanical vibration at a certain resonance frequency.…”
Section: Design Strategy and Wireless Sensing Principlementioning
confidence: 99%
See 1 more Smart Citation